Lincoln Electric POWER WAVE IM986 Operator's Manual page 46

Lincoln electric welder user manual
Table of Contents

Advertisement

E-9
PROBLEMS
(SYMPTOMS)
Arc loss fault on robot.
PROBLEMS
(SYMPTOMS)
Device does not go on Line.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE
2. Conduit leading to the wire feed-
er has bends or twists, which
can reduce the wire feed speed.
3. Conduit leading up to the wire
feeder from the wire reel is too
long.
POSSIBLE
1. 24v bus power.
2. Baud rate.
3. MAC ID
4. Termination
5. Wiring.
6. EDS Files
(Electronic Data Sheet Files)
POWER WAVE® i400
CAUSE
CAUSE
CAUTION
RECOMMENDED
COURSE OF ACTION
2. Remove bends and twists in
conduit leading to the feeder.
3. Use a shorter piece of conduit.
RECOMMENDED
COURSE OF ACTION
1. Verify that LED 10 is on when
the DeviceNet network is pow-
ered. This can be done with the
POWER WAVE® turned on or
off.
2. Verify the baud rate setting is the
same as the DeviceNet Master.
The baud rate is set via the
DeviceNet tab of the Diagnostics
Utility.
3. Verify the DeviceNet MAC ID is
correct. The Mac ID is set via
the DeviceNet tab of the
Diagnostics Utility.
4. Verify that the DeviceNet bus is
terminated correctly.
5. Verify the wiring of all multi-port
taps and field attachable ends.
6. Verify that the correct EDS files
are being used if they are need-
ed. The DeviceNet tab of the
Diagnostics Utility displays the
current Product Code and
Vendor Revision of the POWER
WAVE®.
E-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powerwave i400