centidegree.
Inspect the switch of the fans.
Replace it when the switch is incapable of normal
turn-on or turnoff.
cooling fan
switch
Pressure test of the radiator.
Remove the radiator cover when the cooling liquid is
adequately cooled down; exert a set pressure ( lower than
the open-valve pressure of the cover )on the cooling
system with a radiator cover tester and confirm whether
radiator cover tester
the condition can maintain 6 seconds within the rated
pressure range;
when there is pressure leak,
inspect whether leak
appears in the hose, each joint , mounting point or
checkhole of the water pump.
14.3.2.2 Installation
Install in the reverse order of disassembly.