E-4
PROBLEMS
(SYMPTOMS)
ELECTRICAL FAILURES
Machine fails to come on
(Power LED off)
Power Input incorrect
Input over-current
(Power LED Flashing)
No output current
(Power LED on)
(Output LED off)
Thermal overload
(Thermal LED on)
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. No Input Voltage.
2. Faulty supply plug or cable.
3. Internal fuse blown.
1. Input voltage out of range (less
than 95 or greater than 265VAC).
2. Input current too high due to oper-
ating beyond rated duty cycle.
1. While in TIG mode, Trigger circuit
not mode at 6 pin amphenol.
1. Unit has been operated beyond its
capacity rating.
2. Airflow through machine is
restricted or fan has failed.
If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.
CAUTION
V160-S
RECOMMENDED
COURSE OF ACTION
E-4