Safety Precautions - Sanyo CZP2135V Service Manual

Colour tv
Table of Contents

Advertisement

.
SAFETY PRECAUTIONS
An isolation
transformer
should
be
connected in the power line between the receiver and the AC line before
any
sewice
is performed
on the receiver.
INSTALLATION AND SERVICE ADJUSTMENTS
X-RADIATION PRECAUTION The primary source of X-RADIATION,in television
receiver is the picture tube. The picture tube ia ~
cially constructed
to limit X-RADIATION emissions.
For continued
X-RADIATION protection,
the replacement
tube must be the
same type as the original
including
suffix letter. Excessive
high voltage
mav Produce
potentially
hazardous
X-RADIATION. To
avoid such hazards, the high voltage must be
maintained
within
specified
limit: Refer to this eewice
manual,
high v@tage for
specific
high voltage
limits.
If high voltage exceeds
SpeCifkd
limits, take necessary corrective action. carefully
fOllOWthe inet~c.
tions for + B1 volt power supply adjustment, and high voltage check to maintain the high voltage within the specified limits.
AGC AMJSTMENT
NOTE: Do not attempt this adjustment
with weak signal.
,
1.
:
2.
3.
v
Tune receiver to most clearest (or strongest) VHF station in
your area.
Set brightness and contrast controls to maximum.
Set colour control to minimum.
Set the
AGC (VR101) control to mid-range.
Turn AGC control in direction which causes snow to appear,
then in the opposite direction until the snow just disappears.
SUB BRIGHTNESS AWUSTMENT
1.
Connect a DC meter between
"TP-H"
(positive lead) and
"TP-G"
(negative lead) on main unit.
2.
Receive
the circular pattern.
3. Set brightness
to maximum
and contrast to minimum,
4. Adjust sub brightness control (VR211) for 0.3V
N~E:
If picture
tube
replace.
Check Sub-brightness
ad-
justment.
VERTICAL SIZE AilWSTMENT
1. Tune the receiver to mono-chrome
circular pattern.
2. Adjust vertical size (VR451) control
for full scan.
HORIZONTAL CENTER A~USTMENT
1.
2.
3.
L
B1
Tune the receiver to mono-chrome
circular pattern.
Set the brightness and contrast to maximum.
Adjust Video
Phase
(VR411) for optimum
horiz center po-
sition.
POWER
SUPPLY
AIXH.JSTMENT
1. Connect DC meter to "TP-B" and ground.
Set the + B1 adjustment control (VR311) to mid-range.
2. Set brightness and contrast to minimum.
i
Tune the receiver to an active channel and synchronize pic-
ture.
3. Adjust + B1 adjustment control for 131 ~1.O volt DC.
TUNING DISPLAY WIDTH AWJSTMENT
1. Tune the receiver to mono-chrome
circular pattern.
2. Set the mode switch (SW331 C) to on.
Tuning bar is displayed on screen.
3. Adjust VR 750 on the
V/S UNIT for optimum the tuning bar
width.
Set the mode switch to off.
VIDEO DET. AMJSTMENT
1.
2.
w
Tune receiver to colour bar pattern. (See Fig. 1)
Connect the oscillator to TP-F.
Adjust VR121 for 1.0 f 0.05Vp-p (Video det. waveform),
GREY SCALE AND TRACKING AWUSTMENT
Tune the receiver to mono-chrome pattern.
1.
2
3.
4.
5.
6
7.
8
Set the brightness and the contrast to maximum,the
colour
to normal.
Connect the service tip to KSV-2 (service condition).
Set screen control to minimum. (fully counter-clockwise).
Turn screen control to obtain just visible one coloumd line.
Adjust each bias (VR621-Green,
VR601-Blue,
VR611-Red)
controls alternately
until a dim white line produced.
Re-connect
the service tlp to KSV-l (normal condition).
Adjust red (VR612) and blue (VR602) drive controls alternate
Iy to
produce normal black and white picture.
Check for proper grey scale tracking at all brightness Iewk.
NOTE
If grey scale
adjustment
IS made
after picture tube
replacement,
check
high voltage and
subbrightnees
adjustments.
COLOUR
A~USTMENT
(PAL)
Receive colour bar pattern.
(See Fig. 1)
Set's controls:
brightness
. . . . . . . maximum
colour . . . . . . . . . .. maximum
contrast
. . . . . . . . . mid-range
\
ADJUST
I
REMARKS
Connect the oscilloscope to TP6B on CRT unit.
Adjust VR251, T281 to obtain each lH
r
1 VR251 , T281
I
2
T211
waveform (amplitude) for same as shown
below.
&ll-1+-lH+
~...
""n
u
B-Y WAVE;ORM
Figure 2
Adjust T211 to obtain proper waveform
a:
shown in Figure 2.
FOCUS ACAJUSTMENT
Adjust focus control on the right side of the chassis for well
scanning lines.
HIGH VOLTAGE CHECK
1.
Tune the receiver to the circular pattern.
2. Set brightness and contrast to maximum.
3. Connect a high voltage probe to anode lead at picture tube.
4. High voltage must measure between 26- 28KV.
NOTE: If picture tube replace, check high voltage.
–3–

Advertisement

Table of Contents
loading