MOD
P10 S
P15 S

General Remarks

Caution
The manufacturer cannot be responsible for the damages caused by improper installation
or by failure to follow instructions in this pamphlet. Comply with the installation instructions
before completing electric connection.
Caution
The thermostat has been pre-set at the factory to about 60°C/140°F. To reduce the risk of
scald injury, keep the thermostat at the warm position. (letter M, Fig. 3-4)
Caution
Hydrogen gas can be produced in a hot water system served by this heater that has not been
used for a long period of time (generally 2 weeks or more). Hydrogen gas is extremely
flammable. To reduce the risk of injury under these conditions, it is recommended that the
hot water faucet be opened for several minutes at the kitchen sink before using any electrical
appliance connected to the hot water system. If hydrogen is present, there will probably be
an unusual sound such as air escaping through the pipe as the water begins to flow. There
should be no smoking or open flame near the open faucet at this time.

Installation Instructions

The P 10S and P 15S water heaters can be installed under the sink.
Wall
Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall
Mounting
material and the weight of the heater.
Hang the water heater on the bracket. Tug downwards on the heater to ensure that both
"fingers" of the bracket are seated in the mounting slots.
DIMENSIONS FOR P10 S / P15 S
A
B
14"
10 1/4"
14"
12 1/4"
C
14"
14"
3
D
E
3 1/2"
6 1/8"
3"
6 1/8"