Ariston Heaters User Manual

Ariston heaters user guide

Advertisement

1

Advertisement

Table of Contents
loading

Summary of Contents for Ariston Heaters

  • Page 2: Specifications

    IMPORTANT SAFETY INSTRUCTIONS Warning When using electrical appliances, basic safety precautions to reduce the risk of fire, electric shock or injury to persons should be followed, including: 1.READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER. 2.This water heater must be grounded. Connect only to properly grounded outlet. Use only the 3 prong plug that comes with the water heater.
  • Page 3: Dimensions

    Installation Instructions The P 10S and P 15S water heaters can be installed under the sink. Wall Fasten the supplied mounting bracket to the wall. Use screws that are suitable for the wall Mounting material and the weight of the heater.
  • Page 4: Components Parts

    Pipe Connect the cold water inlet pipe to the inlet nipple (marked with a blue ring - #1, Fig. 4). Connections IMPORTANT: You must use dielectric fittings if inlet piping/fittings are copper or brass. Failure to provide dielectric insulation may result in premature tank or nipple failure and will void warranty.
  • Page 5: How To Use

    Instructions for use Starting and Before connecting the power, fillthe tank and system with water and check for leaks. To be testing certain that all the air is out of the water system, open the hot water faucets on your fixtures until constant water flows from them, otherwise damage to the element may occur.
  • Page 6 1 year) may indicate the presence of galvanic corrosion due to "stray" direct current. In this case, it may be necessary to add a "grounding strap" from the Ariston tank to the copper plumbing. 1. Unplug the power and drain the heater (see previous section).
  • Page 7: Resetting High Limit Switch

    Resetting Occasionally, the high temperature limit shut off device may trigger and shut the High Limit system down. This occurs when water temperature exceeds 190°F and shuts off Switch power to the heating element. The shut off device may also trigger from a power outage or electrical storm.
  • Page 9 ARISTON COVERAGE ARISTON, THROUGH ITS U.S. DISTRIBUTOR CONTROLLED ENERGY CORP., (hereinafter CEC) guarantees this water heater to the Owner (hereinafter "Owner") of the water heater at the original installation location against defects in material and workmanship for the periods specified below.
  • Page 10: Product View

    COMMON SENSE HEAT & HOT WATER TECHNOLOGY Controlled Energy Corp. 340 Mad River Park Waitsfield, VT 05673 800-642-3111 802-496-4436 Fax: 802-496-6924 www.controlledenergy.com...
  • Page 11: Interior Components Diagram

    ARISTON P10 & P15 INTERIOR COMPONENTS DIAGRAM ANODE ROD P10 / P15 574305 HEATING ELEMENT 810847 FLANGE GASKET 570016 HEATING ELEMENT BRACKET HEATING ELEMENT RETAINING NUT TEMPERATURE DIAL COVER SCREW THERMOSTAT WIRE HARNESS GROUND SCREW GROUND SCREW LOCK WASHER THERMOSTAT 691551...