Lochinvar RPD-I-S User Manual page 20

Table of Contents

Advertisement

Venting continued-
3" (7.6 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR
LOW GROUND CLEARANCE INSTALLATIONS
Terminating
(2) 90 Elbows with (1)
90 Elbow
(2) 90 Elbows with (1)
90 Elbow
(2) 90 Elbows with (1)
90 Elbow
(2) 90 Elbows with (1)
90 Elbow
4" (10.2 cm) VENT CONNECTOR LENGTHS FROM INSIDE WALL FOR
LOW GROUND CLEARANCE INSTALLATIONS
Terminating (Reduce 4"
to 3") (Reduce 10.1 cm
to 7.6 cm)
(2) 90 Elbows with (1) 90
Elbow
(2) 90 Elbows with (1) 90
Elbow
(2) 90 Elbows with (1) 90
Elbow
(2) 90 Elbows with (1) 90
Elbow
(2) 90 Elbows with (1) 90
Elbow
HIGH ALTITUDE INSTALLATIONS FOR ELEVATIONS OVER 2,500
FEET (762 m) ABOVE SEA LEVEL
The capacity of the induced draft blower declines with increasing altitude due to
a reduction in the air density. In order to assure safe and reliable performance
of the water heater, contact the supplier for high altitude kit.
TABLE 3
Max Straight
Length ft (m)
# of Elbows
(excl. vent term.)
48,65
gal.
40
1
(12.2)
35
2
(10.7)
3
30 (9.1)
4
25 (7.6)
TABLE 4
# of Elbows
Max straight
(excl. vent
Length ft (m)
term.)
48,65
gal.
85
1
(25.9)
80
2
(24.4)
75
3
(22.9)
70
4
(21.3)
65
5
(19.8)
20
Min
straight
Length
75 gal.
ft (m)
30 (9.1)
5 (1.5)
5 (1.5)
25 (7.6)
20 (6.1)
5 (1.5)
5 (1.5)
15 (4.6)
Min
straight
Length
75 gal.
ft (m)
75
10 (3.1)
(22.9)
70
10 (3.1)
(21.3)
65
10 (3.1)
(19.8)
60
10 (3.1)
(18.3)
55
10 (3.1)
(16.8)
RPD-I-S Rev A