Trouble Shooting

Unit is dead - no lights
Check Power switch is on (down)
Power lead is connected
Fuse on side panel is intact
Power polarity, red wire of lead is positive, black is negative
Voltage to the C-Fax is correct, between 12 and 15V
If all these check ok, or if the fuse fails again after replacement, seek technical
assistance.
No Printing
Check Paper Out light is not flashing, if it is replace the paper
Paper is fitted correctly
Run switch is in Auto or Start position

Replacing the Fuse

The fuse on the side panel can be removed for checking or replacement by unscrewing the
cap anticlockwise.
This fuse protects some very expensive components inside the C-Fax. It must only be
replaced with one of the same rating. The warranty is void if a heavier fuse is used.
The fuse is the standard small size, 20 x 5mm, 2A current rating.
15