6 TON ELECTRIC LOG SPLITTER MODEL NO. S40100600 Operator’s Manual ASSEMBLY & OPERATING INSTRUCTIONS WARNING: All operators must read this manual before operating this log splitter. Follow the safety instructions in the manual and in decals attached to the product.
Table of Contents Page(s) Important Safety Information......................... 1-6 Intended Use ......................... 1 Personal Protective Equipment ....................General Safety ........................Safety Decals ........................Preparation of the Log ......................Work Area ........................... Operation of the Log Splitter ....................Repair and Maintenance Safety ..................... Hydraulic Safety ........................
WARNING: Read and thoroughly understand all instructions and safety information before assembling or operating this log splitter. Failure to do so may cause serious injury or death. Do not allow anyone to operate this log splitter who has not read this manual. As with all power equipment, a log splitter can be dangerous if assembled or used improperly.
SAFETY DECALS Make sure that all safety warning decals are in good condition and readable. Always replace missing or defaced decals. Write us or call 1-800-525-8322 and they will be sent to you at no charge. LOCATION: FRONT, OPERATOR’S SIDE OF BEAM LOCATION: FRONT, NON-OPERATOR’S SIDE OF BEAM SERIAL NUMBER TAG Page 2...
PREPARATION OF THE LOG Both ends of the log should be cut as square as possible to help prevent the log from riding out of the splitter during operation. Do not split logs greater than 20 in. in length. WORK AREA NEVER operate the log splitter on slippery, wet, muddy or icy ground.
Page 6
ALWAYS check for damaged parts before operation. Do not operate until it is repaired. NEVER use an extension cord longer than 25 feet. Minimum cord gage must be 16. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. NEVER stand or ride on the log splitter.
REPAIR AND MAINTENANCE SAFETY NEVER operate your log splitter when it is in poor mechanical condition or in need of repair. ALWAYS unplug the power cable before performing any maintenance and repair. Periodically check that all nuts, bolts, screws, hydraulic fittings and hose clamps are tightened. NEVER alter your log splitter in any manner such as adding a rope or extenstion to the control lever or adding to the width or height of the wedge.
HYDRAULIC SAFETY The hydraulic system of your log splitter requires careful inspection along with the mechanical parts. Be sure to replace frayed, kinked, cracked or otherwise damaged hydraulic components. NEVER check for leaks of hydraulic fluid with your hand. Fluid escaping from a small hole can be almost invisible. Escaping fluid under pressure can have sufficient force to penetrate skin causing serious personal injury or even death.
ASSEMBLY INSTRUCTIONS NOTE: This log splitter was completely assembled at the factory. The product has been filled with hydraulic oil at the factory. Refer to the photo and parts list should it become necessary to disassemble the unit for repair or replacement of parts. Remove the log splitter from the shipping container.
CAUTION: NEVER START OR RUN THE LOG SPLITTER WITHOUT OIL IN THE HYDRAULIC RESERVOIR. ALWAYS CHECK THE LEVEL OF THE HYDRAULIC RESERVOIR BEFORE OPERATION. NOTE: If hydraulic oil is difficult to obtain, Dextron automatic transmission fluid can be substituted. Use only clean oil and take care to prevent dirt from entering the hydraulic reservoir.
Page 11
OPERATION WARNING: ALWAYS WEAR SAFETY GLASSES, SAFETY GLOVES, SAFETY SHOES AND SUITABLE WORK CLOTHING WHEN OPERATING THIS LOG SPLITTER. NEVER WEAR JEWELRY, NECKTIES OR OTHER LOOSE CLOTHING WHICH COULD GET CAUGHT IN MOVONG PARTS. DANGER: KEEP HANDS AND FEET CLEAR OF RAM AND WEDGE AT ALL TIMES. WARNING: KEEP AWAY FROM FLAMMABLE LIQUIDS AND GASES BEFORE STARTING MACHINE Place the log splitter on a sturdy, level surface.
CAUTION: ALWAYS SPLIT THE LOG ALONG ITS GRAIN. IF SPLIT ACROSS THE GRAIN SOME TYPES OF WOOD MAY BURST OR FLY OUT RESULTING IN INJURY. CAUTION: IF THE LOG IS STUCK ON THE WEDGE, RELEASE BOTH HANDS AND UNPLUG THE POWER CABLE IMMEDIATELY.
MAINTENANCE Switch off and unplug power cable before performing any maintenance, adjustment or repair. Make sure to remove any tools and accessories from the work work area when done. Always check the oil level of the hydraulic reservoir before operation. Operating the log splitter without an adequate oil supply will cause severe damage to the pump.
IMPORTANT NOTICE We, the manufacturer, reserve the right to change the product and/or specifications in this manual without notification. The manual is for information usage only and the pictures and drawings depicted herein are for reference only. WARRANTY This log splitter is guaranteed to be free from defects for two full years from the date of purchase. Do not return this product to the store for warranty issues or repair.
TECHNICAL SPECIFICATIONS s t r " 5 " 0 " 8 " 7 " 4 " 1 " 8 * Tonnage and cycle times may vary dependent upon mechanical and environmental conditions. Oregon Products 15000 W. 44th Ave. Golden, CO 80403 Toll Free USA 800-525-8322 www.oregonproducts.com...
Need help?
Do you have a question about the S40100600 and is the answer not in the manual?
Questions and answers