Haier HT1206TXVE Service Manual page 18

Front loading
Hide thumbs Also See for HT1206TXVE:
Table of Contents

Advertisement

Possible
Possible
S/N
Malfunctions
causes
The water
switch does
9
Err5 Alarm
not move
within 8
minutes.
Err6, Err7,
The motor is
10
FErr Alarm
broken.
The water
level is over
11
Err8 Alarm
the
protecting
water level.
Checking Steps
1. Check whether the tap is
open.
2. Check whether the water
pressure is too low.
3. Check whether the
electromagnetic valve is well
linked.
4. Check whether the
pressure switch is well linked.
5. Check whether the
pressure switch hose leaks
gas or not.
6. Check whether the
electromagnetic valve is
damaged.
7. Check whether the
pressure switch is damaged.
8. Check whether the relevant
wiring harness is broken.
1. Check whether the motor is
well linked.
2. Check whether the motor is
damaged ( or over-heated ).
3. Check whether the relevant
wiring harness is broken.
1. Check whether the
drainage pump is well linked.
2. Check whether the
drainage pump is damaged
(short circuit inside).
3. Check whether the
pressure switch is well linked.
4. Check whether the
pressure switch is damaged.
5. Check whether the
pressure switch hose leaks
gas or not.
6. Check whether the relevant
wiring harness is broken.
Troubleshooting
Instrument
Solutions
If normal, go on with the next
Eyeballing
step.
If normal, go on with the next
Eyeballing
step.
If normal, go on with the next
Eyeballing
step.
If normal, go on with the next
Eyeballing
step.
Eyeballing
If normal, go on with the next
Blowing
step.
Check by
hand
If normal, go on with the next
Eyeballing
step.
Multimeter
Eyeballing
If normal, go on with the next
Multimeter
step.
Eyeballing
If normal, change power
Multimeter
drive board.
If normal, go on with the next
Eyeballing
step.
Eyeballing
If normal, go on with the next
Multimeter
step.
Eyeballing
If normal, change power
Multimeter
drive board.
If normal, go on with the next
Eyeballing
step.
Eyeballing
If normal, go on with the next
Multimeter
step.
If normal, go on with the next
Eyeballing
step.
Eyeballing
If normal, go on with the next
Multimeter
step.
Eyeballing
If normal, go on with the next
Blowing
step.
Eyeballing
If normal, change power
Multimeter
drive board.
18