Sharp C6400U Service Manual page 95

Lcd color television
Table of Contents

Advertisement

Adjustment
Adjustment conditions
point
Point 3
LEV30087
MG3G****
MG3B****
MG3R****
MG3Y****
Point 2
LEV20066
MG2G****
MG2B****
MG2R****
MG2Y****
Point 1
LEV10045
MG1G****
MG1B****
MG1R****
MG1Y****
Writing
MSET0003
LC-52/60/70LE640U/C6400U,LC-80LE633U/844U (1st Edition)
Adjustment procedure
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument
Level
Reference value
X=0.272
Point 6
928
y=0.277
X=0.272
Point 5
792
y=0.277
X=0.272
Point 4
608
y=0.277
X=0.272
Point 3
348
y=0.277
X=0.272
Point 2
264
y=0.277
X=0.272
Point 1
180
y=0.277
Remarks
Setting conditions for inspection
AV MODE: [DYNAMIC] (Reset)
Monochro: ON
Active Backlight: OFF
Aging Time: Min. 60 minutes
Brightness specification after adjustment
LC-80LE844U: Min 320cd/m2
5 – 42
Adjustment spec
Inspection spec
±0.0010
±0.0020
±0.0010
±0.0020
±0.0015
±0.0030
±0.0020
±0.0040
±0.0030
±0.0060
±0.004
±0.0080

Advertisement