2.5. Adjustment of white balance
1. White balance adjustment
Adjustment item
Adjustment conditions
1
Setting
2
Execution of auto
[Command]
adjustment
Process mode
KRSW0001
KKT10037
Setting
KYOF0000
OSDS0001
SBSL0016
Multipoint adjustment mode
MSET0001
Adjustment value initializa-
tion
MSET0004
Point 6
LEV60944
MG6G****
MG6B****
MG6R****
Point 5
LEV50800
MG5G****
MG5B****
MG5R****
Point 4
LEV40576
MG4G****
MG4B****
MG4R****
Point 3
LEV30464
MG3G****
MG3B****
MG3R****
Point 2
LEV20264
MG2G****
MG2B****
MG2R****
Point 1
LEV10200
MG1G****
MG1B****
MG1R****
Writing
MSET0003
1) Apply the following settings to the set.
AV MODE: [DYNAMIC]
Backlight: +16
Aging Time: Min. 60 minutes
2) Connect a white balance adjustment jig and the set.
[Adjustment method]
1) Send the "monitor adjustment process" code with the R/C.
2) Set the point 6 to the specified gradation. Set the strongest color as the fixed color
and adjust RGB to the standard value by minus adjustment.
3) Set the point 5 to the specified gradation. Set the correction value of G [(Initial value
of point 5) x (G value of point 6) / (Initial value of point 6)] and adjust RB to the stan-
dard value.
4) Set the point 4 to the specified gradation. Set the correction value of G [(Initial value
of point 4) x (G value of point 6) / (Initial value of point 6)] and adjust RB to the stan-
dard value.
5) Set the point 3 to the specified gradation. Set the correction value of G [(Initial value
of point 3) x (G value of point 6) / (Initial value of point 6)] and adjust RB to the stan-
dard value.
6) Set the point 2 to the specified gradation. Set the correction value of G [(Initial value
of point 2) x (G value of point 6) / (Initial value of point 6)] and adjust RB to the stan-
dard value.
7) Set the point 1 to the specified gradation. Set the correction value of G [(Initial value
of point 1) x (G value of point 6) / (Initial value of point 6)] and adjust RB to the stan-
dard value.
8) Write the adjustment values with the MSET0003 command and turn off AC power.
* Initial value of each point: Set gradation level x 4
[Adjustment values]
•Conform to "Standard set" submitted by Engineering Department.
[LC-32D50U] Teaching set
[Adjustment standard values] Measuring device: [Minolta CA-210] technical measuring
device
Level
Standard value
X=0.272
Point 6
944
y=0.277
X=0.272
Point 5
800
y=0.277
X=0.272
Point 4
576
y=0.277
X=0.272
Point 3
464
y=0.277
X=0.272
Point 2
264
y=0.277
Point 1
X=0.272
200
y=0.277
Note
Test conditions of the set:
2
AV MODE: [DYNAMIC] (Reset)
Monochrome: ON
Aging Time: Min. 60 minutes
5 – 7
Adjustment procedure
Adjustment spec
±0.0012
±0.0012
±0.0012
±0.0012
±0.0012
±0.0020
LC-32HT2U
Test spec
±0.0020
±0.0020
±0.0020
±0.0020
±0.0020
±0.0035