15.2 Setting the Maximum Central Heating Flow Temperature: The boiler is dispatched
with the CH flow temperature set at 85°C. When a lower maximum temperature is required,
such as in the case of under-floor heating, the factory setting can be adjusted to a maximum
of 50°C giving a return temperature of 30ºC, by setting dip switch 'S6' into ON position.