Chargery Power 550B Operating Instructions Manual page 5

1-5s lipo battery smart balance charger
Table of Contents

Advertisement

Lithium polymer battery charging mode
These programs are only suitable for charging LiPo batteries with a nominal voltage of 3.7V/cell.
The type of battery need to be charged at constant current (CC) and constant voltage(CV) mode.
The charge current is dependent on the battery capacity, generally the charge current is less than
1C (the C is battery capacity, for example, if the capacity is 1000mAH, the charge current is less
than 1000mA). The terminal voltage of full charged is very important, it should be 4.2V/cell for the
nominal battery of 3.7V/cell, if the voltage exceeds 4.2V, the battery will explode during charge.
The charge current and nominal voltage as for cell count set on the charge program must always
be correct for the battery to be charged.
You should connect the battery power leads to the output of charger at this program. When you
want to alter the parameter value in the program, press
change the value with DEC or INC. The value will be stored by pressing
again.
LiPo Bat Charge
3.0A
11.1V(3S)
DEC INC
DEC INC
Start/Enter
>3 seconds
Li S:3SER R:3SER
Confirm (enter)
Start/Enter
Li3S 1.2A
12.13V
CHG 011:10 00345
STOP 0.0A
12.59V
011:10 00345
You can also check the parameters you set up on the USER CONFIG PROGRAM by
pressing
INC or DEC
and the real battery temperature.
www.chargery.com
LiPo Smart Balance Charger
The value on the second line sets a charge current and the voltage of the battery pack.
START/ENTER
Press the
After setting the current and voltage press
seconds to start the process. (Charge current: 0.1~5.0A, Voltage: 1~5 series)
When press the
DEC
to set the battery voltage or counts, you can choose the
MODE, 550B will identify the battery count automatically.
The left screen shows the battery count, 'S' is the result set up by you at the previous
screen and 'R' shows the battery count detected by the 550B. If both counts are identical
you can start charging by pressing
go back to previous screen. Then carefully check the battery nominal voltage to charge
again.
The screen shows the present situation during charge process. Li3S means the
battery pack charged is 3 cells in series even the cell count you selected is not
3. On the top line it means battery count, charging current and battery voltage from
left to right. While for the bottom line, it means CHARGE, charging time and capacity
charged.
To change the charge current, press
DEC or INC
current by pressing the
To stop the charge, press
The battery is fully charged.
button; include Input voltage limit, Battery temperature Limit,
START/ENTER
button, and then press the
START/ENTER
START/ENTER
button. If not, press STOP button to
START/ENTER
button.
STOP
button.
CY- 550B.
button to make it blink then
START/ENTER
button once
DEC or INC
to set value.
button for more than 3
AUTO
button. Decrease or increase the
page 5 total 11