Vivotek IP8173H User Manual page 199

Fixed network camera
Table of Contents

Advertisement

state after duration.
return
<return page>
Return Code
Description
200
The request is successfully executed.
400
The request cannot be assigned, ex. incorrect parameters.
Examples:
setvi.cgi?vi0=0(10000)1(15000)0(20000)1
No multiple duration.
setvi.cgi?vi3=0
VI index is out of range.
setvi.cgi?vi=1
No VI index is specified.
503
The resource is unavailable, ex. Virtual input is waiting for next state.
Examples:
setvi.cgi?vi0=0(15000)1
setvi.cgi?vi0=1
Request 2 will not be accepted during the execution time(15 seconds).
Open Anystream (capability.nanystream > 0)
Note: This request requires Viewer access privileges.
Syntax:
For HTTP push server (MJPEG):
http://<servername>/videoany.mjpg?codectype=mjpeg[&resolution=<value>&mjpeg_quant=<value>&mjpeg
_qvalue=<value>&mjpeg_maxframe=<value>]
For RTSP (MPEG4), the user needs to input the URL below into an RTSP compatible player.
rtsp://<servername>/liveany.sdp?codectype=mpeg4[&resolution=<value>&mpeg4_intraperiod=<value>&mpe
g4_ratecontrolmode=<value>&mpeg4_quant=<value>&mpeg4_qvalue=<value>&mpeg4_bitrate=<value>&m
peg4_maxframe=<value>]
For RTSP (H264), the user needs to input the URL below into an RTSP compatible player.
rtsp://<servername>/liveany.sdp?codectype=h264[&resolution=<value>&h264_intraperiod=<value>&h264_r
cannot accept new requests.
Redirect to the page <return page> after the request is
completely assigned. The <return page> can be a full URL
path or relative path according the current path. If you omit
this parameter, it will redirect to an empty page.