Page 7
NPM-5 PAMS Technical Documentation Troubleshooting $EEUHYLDWLRQV XVHG Baseband Cellular Mobile Telephone Direct Current Electro Static Dicharge Frequency of signal (measured with Spectrum Analyzer) Low frequency (measured with oscilloscope) Local Oscillator Power of signal in decibels (dB) (measured with Spectrum Analyzer) Power Amplifier Printed Circuit Board Phase Locked Loop...
Page 14
NPM-5 CMT Troubleshooting PAMS Technical Documentation )ODVK SURJUDPPLQJ GLDJUDP )LJXUH )ODVK SURJUDPPLQJ WURXEOHVKRRWLQJ Flash programming doesn’t work If fault information from Prommer is: a) MCU doesn’t boot See section: (2) b) Serial dataline failure c) Serial clock line failure Connect R224 (towards N201) (WDDISX) to GND.
Page 15
NPM-5 PAMS Technical Documentation CMT Troubleshooting )ODVK SURJUDPPLQJ GLDJUDP )LJXUH )ODVK SURJUDPPLQJ WURXEOHVKRRWLQJ Flash programming doesn’t work Check for activity on control lines for SRAM : J323 External RAM error Defective SRAM (D302) (RAMSelX) Defective MAD2 (D300) or short circuit under the SRAM Algorithm file or alias...
Page 21
NPM-5 PAMS Technical Documentation CMT Troubleshooting 6,0 FDUG UHMHFWHG HUURU )LJXUH 6,0 FDUG HUURU "SIM card rejected" Vsim according to spec.: 2,8V min. (3V SIM card) Defective CCONT (N201) 4,5V min. (5V SIM card) ATR data can be seen at C222 towards Check X400 and R213 R213...
Page 23
NPM-5 PAMS Technical Documentation CMT Troubleshooting )LJXUH ([WHUQDO HDUSLHFH Headset earpiece does not work and there are no mechanical problems Check R108, C103, C408 5HSODFH &2%%$ 1 )LJXUH ([WHUQDO PLFURSKRQH Headset microphone does not work and there are no mechanical or electrical problems Check R100, R101, R105 (XMICIN line towards...
Page 24
NPM-5 CMT Troubleshooting PAMS Technical Documentation &KDUJLQJ (UURU )LJXUH 1R GHWHFWLRQ RI FKDUJHU Nothing happens when a charger is connected to the phone The voltage at R210 towards Check F200, L202, R209, R210 R209 > 0,4V Replace CCONT (N201) )LJXUH 1RW &KDUJLQJµ...
NPM-5 PAMS Technical Documentation RF Troubleshooting 5) 7URXEOHVKRRWLQJ 7ZR W\SHV RI PHDVXUHPHQWV DUH XVHG LQ WKH IROORZLQJ ,W ZLOO EH VSHFLILHG LI WKH PHDVXUH PHQW W\SH LV 5) RU /) • RF measurements should be done with a Spectrum Analyzer and a high-frequency 500 ohm passive probe, for example HP54006A.
Page 44
NPM-5 RF Troubleshooting PAMS Technical Documentation 7URXEOHVKRRWLQJ FKDUW IRU 3&1 WUDQVPLWWHU )LJXUH 3&1 7; WURXEOHVKRRWLQJ Measure TX Measure TX Measure TX Measure TX With Osc check: Measure TX power power on "ANT" power on "Pout". power on "Pin". power unbal T503. VTX = 2.7V + on DCS_Tx.
NPM-5 UI Module Troubleshooting PAMS Technical Documentation • U801 FMR ,W LV LPSRUWDQW WKDW D VHUYLFH SHUVRQQHO KDV D OLVW RI YDOLG ¦OLYH§ )0 FKDQQHO IRU OLVWHQLQJ YHULILFDWLRQ 7KHVH GLDJQRVWLF VWHSV GR QRW UHTXLUH DQ\ VLJQDO JHQHUDWRU Diagnostic Tests: • Check the stereo headset has proper contact with the UI module since the ste- reo headset is used as antenna to FM signal •...
Page 78
NPM-5 UI Module Troubleshooting PAMS Technical Documentation $SSHQGL[ & 7URXEOHVKRRWLQJ IORZ FKDUWV *HQHUDO 8, WURXEOHVKRRWLQJ )LJXUH *HQHUDO 8, WURXEOHVKRRWLQJ USB Detection Malfunction Is MP3/FM Go to MP3/FM working? Troubleshooting section Plug in USB cable with PC turned on USB_DET_INT Check R409, R410 voltage correct?
NPM-5 PAMS Technical Documentation UI Module Troubleshooting 'LVSOD\ PRGXOH PDOIXQFWLRQ Figure 52: Display Module - No Display, Display Module Malfunction Replace a good display module Check the soldering Is the display and connection of the module OK? 36-pin B2B connector to UI board Change the display module...
Page 80
NPM-5 UI Module Troubleshooting PAMS Technical Documentation 1R EDFNOLJKW LQ /&' RU NH\ERDUG )LJXUH LCD/Keyboard LED - No Light LCD/Keyboard LED Malfunction Ensure CMT is functioning well Measure VBAT with DVM Check the soldering and connection of Is the voltage the 36-pin B2B of VBAT OK? connector to UI...
Page 81
NPM-5 PAMS Technical Documentation UI Module Troubleshooting .H\ERDUG RU KRW NH\V GR QRW UHVSRQG )LJXUH .H\ERDUG+RWNH\ GR QRW UHVSRQG Keyboard/Hotkey Malfunction Side Keys Malfunction? Check the Check if SW753, alignment of SW754, SW755, SW756 domesheet side keys are intact Check if pull-down resistors Ensure there is no R701, R703, R704, R705,...
Page 82
NPM-5 UI Module Troubleshooting PAMS Technical Documentation 1R DXGLR LQ 0XVLF 3OD\HU )LJXUH 0XVLF SOD\HU QR DXGLR Music Player - No Audio Ensure the stereo headset has proper contact with UI board Check if Check resistor ST_DET voltage R607, R608 correct Check R304, R305...
Page 84
NPM-5 UI Module Troubleshooting PAMS Technical Documentation )0 UHFRUGLQJ QRW SRVVLEOH )LJXUH )0 UHFRUGLQJ QRW SRVVLEOH FM/Line-In Recording Malfunction Is MP3 Go to MP3 functioning Troubleshooting section. Is FM Go to FMR Radio Troubleshooting functioning section. Run FM/Line-In Recording Function Ensure there is analog signal at...
Page 85
NPM-5 PAMS Technical Documentation UI Module Troubleshooting 6WHUHR DXGLR PDOIXQFWLRQ )LJXUH 6WHUHR DXGLR PDOIXQFWLRQ Phone Audio Malfunction (Stereo Headset) Is MP3 Go to MP3 functioning Troubleshooting section. Make a phone call. Ensure the line is connected. Check if Check the soldering there is voice signal and connection of the appear at XEARP and...
NPM-5 UI Module Troubleshooting PAMS Technical Documentation 6WHUHR KHDGVHW PLFURSKRQH PDOIXQFWLRQ )LJXUH 6WHUHR KHDGVHW PLFURSKRQH PDOIXQFWLRQ External Mic Replace and test Is the new Replace the stereo Malfunction with a good stereo stereo headset headset (Stereo Headset) headset with mic working? Check B2B connector.
Page 87
NPM-5 PAMS Technical Documentation UI Module Troubleshooting 3KRQH VSHDNHU PDOIXQFWLRQ )LJXUH 3KRQH VSHDNHU PDOIXQFWLRQ Internal speaker malfunction Replace a good internal speaker and test it Is the new Replace the speaker working? speaker Check B2B connector. Ensure the connectivity of EAR+, EAR- (Pin32 and pin 31 of J301) to the UI module Check FL604 and...
Page 88
NPM-5 UI Module Troubleshooting PAMS Technical Documentation 3KRQH PLFURSKRQH PDOIXQFWLRQ )LJXUH 3KRQH PLFURSKRQH PDOIXQFWLRQ Internal mic malfunction Replace a good system connector and test it Is the new Replace the mic working? system connector Check B2B connector. Ensure the connectivity of MIC+, MIC- (Pin35 and pin 34 of J301) to the UI module Check FL601 and...