Fujitsu ASU15RLS2 Service Manual

Fujitsu ASU15RLS2 Service Manual

Split type room air conditioner wall mounted type
Hide thumbs Also See for ASU15RLS2:

Advertisement

SPLIT TYPE
ROOM AIR CONDITIONER

WALL MOUNTED TYPE

Indoor unit

ASU15RLS2
CONTENTS
SPECIFICATIONS. . . . . . . . . . . . . . . . . . .
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .
ERROR DETECTION . . . . . . . . . . . . . . .
PARTS (INDOOR UNIT) . . . . . . . . . . . . .
PARTS (OUTDOOR UNIT) . . . . . . . . . . .
ACCESSORIES . . . . . . . . . . . . . . . . . . .

Outdoor unit

AOU15RLS2
1
2
3
4
5
9
13
15
20
23

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASU15RLS2

  • Page 1: Table Of Contents

    ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor unit Outdoor unit ASU15RLS2 AOU15RLS2 CONTENTS SPECIFICATIONS....DIMENSIONS ..... .
  • Page 2: Specifications

    SPECIFICATIONS ELECTRICAL DATA NOISE LEVEL TYPE Cool & heat inverter High 45 dB Medium INDOOR UNIT ASU15RLS2 40 dB INDOOR UNIT Cooling OUTDOOR UNIT AOU15RLS2 33 dB Quiet COOLING CAPACITY 14,500 Btu/h 25 dB High HEATING CAPACITY 18,000 Btu/h 45 dB...
  • Page 3: Dimensions

    DIMENSIONS unit : inch (mm) INDOOR UNIT 34-1/4 (870) 7-9/32 (185) Drain pipe diameter 16.2 mm Liquid pipe diameter : 1/4 inch (6.35 mm) Gas pipe diameter : 1/2 inch (9.52 mm) OUTDOOR UNIT 11-13/32 (290) 31-3/32 (790) 21-1/4 (540) 2011.12.28...
  • Page 4: Refrigerant System Diagram

    REFRIGERANT SYSTEM DIAGRAM Heat exchanger (indoor unit) Muffler 2-Way valve 3-Way valve Compressor Muffler Refrigerant direction Strainer Cooling Heating 4-Way valve Refrigerant pipe diameter Expansion valve Liquid : 1/4" (6.35 mm) Gas : 1/2" (12.7 mm) Heat exchanger (outdoor unit) Strainer 2011.12.28...
  • Page 5: Circuit Diagram

    CIRCUIT DIAGRAM INDOOR UNIT OUTDOOR UNIT CONTROLLER PCB ASSY ( MAIN PCB ) CN201 WHITE ORANGE WHITE YELLOW LOUVER CN42 CN40 CN200 CN400 WHITE PINK INDICATOR PCB ASSY 1 2 3 4 5 1 2 3 4 5 6 7 8 9 1 2 3 4 WHITE BLUE...
  • Page 6: Indoor Pcb Circuit Diagram

    EARTH TERMINAL INDOOR PCB CIRCUIT DIAGRAM GREEN OUTDOOR UNIT THERMAL EMI FILTER FUSE 102 ESD-R-19 CONTROL UNIT RTCB-19-10-10 EZ-01107HSE WHITE TERMINAL BLACK BLACK THERMISTOR ( PIPE TEMP. ) BLACK 2013485-1 B04B-PL I RK-1 BLACK THERMISTOR ( ROOM TEMP. ) BLACK FAN MOTOR BLACK WHITE...
  • Page 7 D1FL20U 2013485-1 <SS11V> 0.6A - 10mH 340V S1NBC60 100/ 100k CONTROLLER PCB ASSEMBLY TO TERMINAL <1/10W> 0.01 3.15A <F> ( MAIN PCB ) 250V 470V <ERZ10V> <LE> 0.01 K10CH-110DHSE-C1 D1FL20U <F> EE16 5V-2 330/ BLm18 ST03D-140 RD8.2FM D1FL20U <BD102> 420V 470/ I C8 TNY277...
  • Page 8 INDOOR UNIT INDICATOR PCB ASSEMBLY K10CX-1000HSE-D0 CN201 8 - JB / PL I D204 L=250 #26 / 1061 UDZS6.2B D201 SLR-343ECT <GREEN> D205 UDZS6.2B D202 SL I-343DCT <ORANGE> SW201 D206 KSHC611BT UDZS6.2B D203 SLR-343ECT <GREEN> R202 <1/4W> C203 C204 <F> I C201 GP1UM271R R201...
  • Page 9 TO CONTROLLER PCB ASSEMBLY 390V D303 CN301 T301 JM303 SJH20-09WSF SW1614-1 RF101L2S R301 C302 390k 1000p R309 C306 <1/4W> <E> 100/ R302 <1/10W> <1/4W> D301 UF4007 + C301 D302 RF101L2S 450V R306 I C301 1.0k LNK603 R303 R304 C311 <1/10W> 100/ BP_M C305...
  • Page 10: Outdoor Pcb Circuit Diagram

    OUTDOOR PCB CIRCUIT DIAGRAM INVERTER ASSEMBLY EZ-0111BHUE EARTH UL1015 AWG14 EMI FILTER UL1015 WHITE ZCAT2132-1130 AWG14 UL1015 BLACK AC208 - 230V AWG14 60Hz BLACK UL1015 UL1015 F200 AWG14 TM101 AWG20 ORANGE 250V UL1015 AWG20 F100 WHITE I NDOOR UNIT UL1015 UL1015 250V AWG20...
  • Page 11 CN200 1-1747052-2 FC51FL x 2 FH200 FH201 1SS355 DC VOLT I N R601 F201 OUTDOOR UNIT 1.0k R603 I C5 3.15A <1/10W> 150k 2200p 220/ CT600 250V 7818 MAIN PCB D600 <1/10W> C211 <2W> <E> CT-1B DAN217U P-AN-CT TM601 C601 K07BS-110BHUE-C1 560k 450V...
  • Page 12 OUTDOOR UNIT TRANSISTOR PCB ( I P M ) K10AY-100AHUE-TR0 R360 C209 - C211 C221 C222 C332 C302 0.1 <F> 100/ L300 <1/2W> <F> <F> <F> BL02Rn1 TM303 TM101 D303, D302, D301 D307 ORANGE US1J x 3 RD24FM TM102 TM304 BROWN BLACK D100...
  • Page 13: Filter Pcb

    OUTDOOR UNIT CAPACITOR PCB K05DG-0700HUD-P0 WHITE YELLOW C201 C202 660/ 660/ 450V 450V BLUE VIOLET POWER_G CT OUT OUTDOOR UNIT ORANGE PTC OUT BLACK GRAY FILTER PCB R100 K05CW-1101HUE-FL0 PTC THERMISTOR ORANGE ZPR0RCH400 R101 PTC THERMISTOR ZPR0RCH400 ORANGE L102 N200500K1D7C VA100 C109 C104...
  • Page 14: Error Detection

    Indoor unit display ER R OR D ETEC TION INDOOR UNIT REMOTE CONTROL If you use a wireless remote control, the lamp on the photo detector unit will output error codes by way of blinking patterns. If you use a wired remote control, error codes OPERATION indicator lamp (green) will appear on the remote control display.
  • Page 15 OUTDOOR UNIT ERROR Discharge temperature abnormal 0.5 second on / 0.5 second off IPM overcurrent protection 0.1 second on / 0.1 second off Thermistor abnormal CT abnormal 2.0 second on / 2.0 second off 0.1 second on / 2.0 second off Compressor location abnormal 5.0 second on / 5.0 second off Fan abnormal...
  • Page 16: Parts (Indoor Unit)

    PARTS INDOOR UNIT Ref. Description Part number Bracket Panel 9318913002 Wire Cover 9318911008 Wire Shield 9318919004 Under Cover 9318879001 Louver (Upper) 9318880007 Louver (Lower) 9318881004 Air Clean Filter Assy 9317250009 Remote Control 9319634005 Remote Control Holder 9318912005 2012.01.05...
  • Page 17 INDOOR UNIT Front panel Ref. Description Part number Front Panel Total Assy 9319348209 Air Filter 9318883008 Intake Grille Assy 9319351186 Front Panel 9318876000 Front Panel Cover T 9318909005 Display Plate Holder L 9318894004 Display Plate Holder R 9318895001 Display Plate R 9318893007 Arm Cover 9318900002...
  • Page 18 INDOOR UNIT Evaporator Ref. Description Part number Evaporator Total Assy 9319327013 Joint Pipe Assy 9319322018 Joint Pipe Holder 9318901009 Base 9318874006 Filter Guide 9318887006 Evaporator Holder L 9318875003 Air Seal 9319295008 2012.01.05...
  • Page 19 INDOOR UNIT Control box Ref. Description Part number Ref. Description Part number Cover Shield A 9318916003 Gear B 9319294001 Control Box 9318882018 Panel Gear 9319293004 43 Box Shield Assy 9319344003 Gear Case 9318903003 Controller PCB Assy 9708713229 Switch Case 9319332000 Terminal 9900638016 Grille Key Top...
  • Page 20 INDOOR UNIT Casing assy Ref. Description Part number Ref. Description Part number Fan Motor 9602947010 Pipe Bracket 9318889000 Crossflow Fan Assy 9319361000 Panel Cover 9319296005 Bearing C Assy 9306628017 Louver Holder 9318886009 Casing Assy 9319342009 R and L Louver 9318885002 Casing 9318873009 Motor Step...
  • Page 21: Parts (Outdoor Unit)

    PARTS OUTDOOR UNIT Ref. Description Part number 1 Protective Net 9331640008 2 Top Panel Assy 9318464023 3 Front Panel Assy 9318463033 Cabinet Left Assy 9318461015 5 Cabinet Right Assy 9316044050 Switch Cover 9317692021 7 Base Assy 9316885066 8 Motor Bracket Assy 9316041011 9 Fan Motor 9602724000 10 Propeller Fan...
  • Page 22 OUTDOOR UNIT Ref. Description Part number Condenser Total Assy 9317089128 Compressor Assy 9318334005 Valve Bracket 9331649001 2-way Valve Assy 9317171014 3-way Valve Sub Assy 9317109062 4-way Valve Assy 9318457018 Solenoid 9970110023 Pulse Motor Valve Assy 9315587022 Expansion Valve Coil 9970095030 2012.01.05...
  • Page 23 OUTDOOR UNIT Ref. Description Part number Main PCB 9708511276 Transistor PCB 9708646077 Filter PCB 9709217023 Capacitor PCB 9708514017 ACTPM 9707592016 Heatsink 9318614015 Choke Coil 9900223014 Terminal 6P 9900016081 Outdoor Thermistor 9900544041 Thermistor Assy 9900648008 2012.01.13...
  • Page 24: Accessories

    ACCESSORIES INDOOR UNIT Name and Shape Part number Bracket panel 9318913002 Remote control 9319634005 Remote control holder 9318912005 Battery (penlight) 0600185077 Cloth tape 9308117007 Tapping screw (big) 0700076046 4 x 25) Tapping screw (small) 3 x 12) 0700019036 OPTION Name and Shape Part number Air cleaning filter (ion deodorant)
  • Page 25 1112G4002...

This manual is also suitable for:

Aou15rls2

Table of Contents