Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Softeners. We are committed to ensuring
that you are totally satisfied.
If you have any problems, don't go back to the store - please contact us ! Most issues can be resolved over the
phone.
System Specifications .................................................................................................... 2
How Your Water Conditioner Works ............................................................................. 2
Cautions Before Installation ................................................................................................. .. 2
Installation .................................................................................................................... 3
a) Electrical Requirements .................................................................................... .......... 3
b) Unpacking the unit ................................................................................................. ...... 3
c) Plumbing the Softener ............................................................................................. .... 3
d) Start-up and Programming ........................................................................................ .. 5
a. Control Valve ...................................................................................................... 5
b. Level 1 Programming ....................................................................................... .. 5
c. Level 2 Programming ...................................................................................... .. 6
Other Features ............................................................................................................. 8
Maintenance ................................................................................................................. 8
Troubleshooting ............................................................................................................ 9
Exploded Diagram & Parts List ............................................................................................ . 10
Warranty ..................................................................................................................... 10
T Series Water Softener
Installation & Operation Manual
(Please save for future reference)
Help Line : 1-800-667-8072
Monday to Friday 8:30 AM to 5:00 PM EAST
Website : www.rainfresh.ca

TABLE OF CONTENTS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 30T and is the answer not in the manual?

Questions and answers

joe
March 13, 2025

How do i remove the brine elbow for the softner

1 comments:
Mr. Anderson
March 13, 2025

The document does not provide specific instructions on removing the brine elbow on a Rainfresh 30T water softener. However, based on standard quick-connect fittings, you may need to press the collet (small ring) around the fitting while pulling the tube out. If further clarification is needed, refer to the manual or contact the manufacturer.

This answer is automatically generated

Subscribe to Our Youtube Channel

Summary of Contents for Rainfresh 30T

  • Page 1: Table Of Contents

    Installation & Operation Manual (Please save for future reference) Thank you for purchasing one of our ENVIROGARD / Rainfresh Water Softeners. We are committed to ensuring that you are totally satisfied. If you have any problems, don’t go back to the store – please contact us ! Most issues can be resolved over the phone.
  • Page 2: System Specifications

    Iron < 0.5 PPM; Manganese < 0.05 PPM ; Turbidity < 1 NTU ; Free Chlorine < 0.5 PPM ; Hydrogen Sulphide – Nil ; Organics – Nil. If feed water quality exceeds above limits, please call Rainfresh for advice on additional treatment that may be necessary.
  • Page 3: Installation

    INSTALLATION Optional bypass to outside faucets Cold water to house City Water Supply Water Meter Hot water to house Optional Rainfresh UV Disinfection System & filter for well water Rainfresh Sediment Filter Pressure Tank (Recommended) To air-gap drain Well Water...
  • Page 4 If you have a private well, turn the power off to the pump then shut off the main water shut off valve. If you have municipal water, simply shut off the main valve. Go to a faucet, (preferably on the lowest floor of the house) turn on the cold water until all pressure is relieved and the flow of water stops.
  • Page 5: D) Start-Up And Programming

    START UP & PROGRAMMING The control valve is controlled with simple, user-friendly electronics displayed on an LCD screen. When power is first supplied, the valve electronics may take up to two minutes to initialize. During this time the screen will show “INTIALIZING WAIT PLEASE”.
  • Page 6: Level 2 Programming

    STEP 2 : Setting Current Date Press “ SET/REGEN” again Press “ DOWN” arrows to Press “ SET/REGEN” Now press “ to accept the month and advance to CURRENT DATE once and the MONTH UP OR DOWN” arrows advance to change the to change the month value flashes.
  • Page 7 Unit Capacity For 30T, default = 20,000 at 6lbs/ft³. Set at 30,000 grains if you chose 15 lbs salt/ft³ in step7 For 45T, default = 30,000 at 9lbs/ft³. Set at 45,000 grains if you chose 15 lbs salt/ft³ in step7 For 60T, default = 40,000 at 12lbs/ft³.
  • Page 8: Other Features

    OTHER FEATURES Control Operation During a Power Failure In the event of a power failure, the valve will keep track of the time and day for 48 hours. The programmed settings are stored in a non-volatile memory and will not be lost during a power failure. If power fails while the unit is in regeneration, the valve will finish regeneration after power is restored.
  • Page 9: Troubleshooting

    Trouble Shooting Issue Possible Cause Possible Solution A. Unit fails to initiate a 1. No power supply. Check electrical service, fuse, etc. regeneration cycle. 2. Defective circuit board. Replace faulty parts. 3. Power failure. Reset time of day. B. Water is hard. 1.
  • Page 10: Exploded Diagram & Parts List

    PART # DESCRIPTION Control Valve Top Distributor Central Tube (Riser) Media Tank for model 30T – 9”x 48” Media Tank for model 45T – 10”x 54” Media Tank for model 60T– 12”x 52” Softener Resin Safety Brine Valve Brine Tank (salt tank)

This manual is also suitable for:

45t60t