Physical/Electrical Specifications; Ac Power Requirements; Dc Power Requirements - Seagate ST34501FC Cheetah 4LP Product Manual

Cheetah 4lp fc disc drive
Hide thumbs Also See for ST34501FC Cheetah 4LP:
Table of Contents

Advertisement

Cheetah 4LP FC Product Manual, Rev. A
6.0

Physical/electrical specifications

This section provides information relating to the physical and electrical characteristics of the drive.
6.1

AC power requirements

None.
6.2

DC power requirements

The voltage and current requirements for a single drive are shown below.Values indicated apply at the drive
connector.
Table 1:
DC power requirements
Voltage Regulation
Avg idle current
Max start current (peak DC)
Delayed motor start (max)
Operating current:
Typical
Maximum
Max (peak)
[1]
Measured with average reading DC ammeter. Instantaneous +12V current peaks will exceed these val-
ues.
A –10% tolerance is allowed during initial spindle start but must return to ±5% before reaching 10,033
[2]
RPM. The ±5% must be maintained after the drive signifies that its power-up sequence has been com-
pleted and that the drive is able to accept selection by the host initiator.
[3]
See +12V current profile in Figure 3.
[4]
This condition occurs when the Motor Start option is enabled and the drive has not yet received a Start
Motor command.
[5]
See paragraph 6.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and
transient response.
[6]
At power-up the motor current regulator limits the 12V current to an average value of less than 2.5 - 2.7A,
although instantaneous peaks may exceed this value. These peaks should measure 5 msec duration or
less.
[7]
Operating condition means a third stroke seek at OD and Read One track. A command is issued every
0.108 seconds.
[8]
All power-saving features enabled.
General DC power requirement notes.
1. Minimum current loading for each supply voltage is not less than 4% of the maximum operating current
shown.
2. The +5V and +12V supplies should employ separate ground returns.
3. Where power is provided to multiple drives from a common supply, careful consideration for individual
drive power requirements should be noted. Where multiple units are powered on simultaneously, the peak
starting current must be available to each device.
ST34501FC
+5V
±5%
Notes [5]
(Amps)
[1] [8]
1.000
[3] [6]
1.074
[1] [4]
0.634
[7]
[1] [6]
1.036
[1]
1.083
1.239
+12V
±5%[2]
(Amps)
0.874
2.239
0.177
1.028
1.075
2.196
17