LG 32LS3500 Service Manual page 17

Hide thumbs Also See for 32LS3500:
Table of Contents

Advertisement

Manual W/B process
*
After enter Service Mode by pushing ADJ key,
Enter White Balance by pushing
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Tool Option5
5. Country Group
6. ADC Calibration
7. White Balance
8. 10 Point WB
9. Test Pattern
10. EDID D/L
11. Sub B/C
12. Touch Sensitivity Setting
13. Ext. Input Adjust
After You finish all adjustments, Press In-start button and compare Tool option and Area option
value with its BOM, if it is correctly same then unplug the AC cable.
If it is not same, then correct it same with BOM and unplug AC cable.
For correct it to the model s module from factory JIG model.
Push the IN-STOP KEY after completing the function inspection.
4.2 DDC EDID Write (RGB 128Byte )
Connect D-sub Signal Cable to D-Sub Jack.
Write EDID DATA to EEPROM (24C02) by using
Check whether written EDID data is correct or not.
* For SVC main Ass y, EDID have to be downloaded to Insert Process in advance.
4.3 DDC EDID Write (HDMI 256Byte)
Connect HDMI Signal Cable to HDMI Jack.
Write EDID DATA to EEPROM(24C02) by using
Check whether written EDID data is correct or not.
* For SVC main Ass y, EDID have to be downloaded to Insert Process in advance.
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
using adjusts Remote control.
key at 7. White Balance .
EZ ADJUST
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern
Backlight
Reset
DDC2B
protocol.
DDC2B
protocol.
- 17 -
Cool
172
172
192
64
64
64
ON
100