Electrical Requirements - Samsung DV52J8700E(G) series User Manual

Hide thumbs Also See for DV52J8700E(G) series:
Table of Contents

Advertisement

Installation
Commonwealth of Massachusetts installation instructions
Your dryer must be installed by a licensed plumber or gas fitter. A "T" handle manual gas
valve must be installed in the gas supply line to your dryer. If a flexible gas connector is used
to install your dryer, the connector can be no longer than 3' (36").
WARNING
• Gas leaks may occur in your system, creating a dangerous situation.
• Gas leaks may not be detected by smell alone.
• Gas suppliers recommend you purchase and install a UL-approved gas detector.
• Install and use in accordance with the manufacturer's instructions.

Electrical requirements

NOTE
The wiring diagram is located on the plate below the control panel or frame back.
WARNING
• Improperly connecting the equipment grounding conductor can result in a risk of electric
shock.
Check with a qualified electrician or serviceman if you are in doubt as to whether your
dryer is properly grounded. Do not modify the plug provided with your dryer – if it
doesn't fit the outlet, have a proper outlet installed by a qualified electrician.
• To prevent unnecessary risk of fire, electrical shock, or personal injury, all wiring and
grounding must be done in accordance with local codes, or in the absence of local codes,
with the National Electrical Code, ANSI/NFPA No. 70-Latest Revision (for the U.S.) or the
Canadian Electrical Code CSA C22.1 – Latest Revisions and local codes and ordinances. It
is your responsibility to provide adequate electrical services for your dryer.
• All gas installations must be done in accordance with the national Fuel Code ANSI/Z2231
– Latest Revision (for the U.S.) or CAN/CGA – B149 Installation Codes – Latest Revision
(for Canada) and local codes and ordinances.