Symptom or error
2110
Read error on HDD0 (Main hard disk drive)
2112
Read error on HDD1 (Ultrabay hard disk
drive)
Error messages
Symptom or error
Device address conflict.
Allocation error for device.
Failing bits: nnnn.
Invalid system configuration data.
I/O device IRQ conflict.
Hibernation error.
Fan error.
Thermal sensing error.
Authentication of system services failed.
Press <Esc> to resume.
Symptom-to-FRU index
FRU or action, in sequence
1. Reseat the hard disk drive.
2. Main hard disk drive.
3. System board.
1. Reseat the hard disk drive.
2. Ultrabay hard disk drive.
3. System board.
FRU or action, in sequence
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load "Setup Defaults" in the BIOS
Setup Utility.
2. Backup battery.
3. System board.
1. Restore the system configuration to
what it was before the computer
entered hibernation mode.
2. If memory size has been changed,
re-create the hibernation file.
1. Fan.
2. Thermal grease.
3. System board.
System board.
The Predesktop Area in the HDD is
corrupted. Restore it from a recovery disc.
ThinkPad X60 and X60s
47