Fujitsu ASTA24LFC Operating Manual page 17

Heat & cool model (reverse cycle) room air conditioner wall mounted type
Hide thumbs Also See for ASTA24LFC:
Table of Contents

Advertisement

OPERATING TIPS
Temperature and Humidity Range
Outdoor temperature
Indoor temperature
G If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may
operate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of
lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.
G Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary
dwellings.
G If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor
unit, and drip onto the floor or other objects underneath. (About 80% or more).
G If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device,
the outdoor unit may stop operation for certain period of time.
9315345301_OM_EN_body
Cooling Mode
About -10 to 46 °C
About 18 to 32 °C
16
Dry Mode
About -10 to 46 °C
About –15 to 24 °C
About 18 to 32 °C
About 30 °C or less
3/22/10, 10:40 AM
Heating Mode
16