Spirit Oil-Fired Highboy Furnace Specifications
Model
Heat Input Rate (BTUH):
Output (BTUH):
Nominal Temp. Rise (deg. F.):
Minimum AFUE Rating (%):
Gross Heat Exchange Area (sq. ft.):
Casing Height (in.):
Casing Width (in):
Casing Depth (in.):
Nominal Flue Outlet Dia. (in.):
Height from Floor to Center of Flue (in.):
Supply Air Outlet Size (in. x in.):
Return Air Inlet Size (in. x in.):
Air Filter Quantity & Size (in. x in.):
Approx. Shipping Weight (lb.):
Electrical Requirements (VAC/Hz/Ph):
Total Current (Amps.):
Max. Fuse Size (Amps.):
Blower Specifications:
Blower Motor Size (HP):
Motor Type & Number of Speeds:
High Speed Airflow (SCFM) @ 0.4 in.
W.G. External Static Pressure:
Burner Specifications:
Air Tube Length (in.):
Burner Head Type:
Fuel Type:
Nozzle Rating for Beckett AF (GPH):
Spray Angle (Deg.):
Spray Pattern:
Oil Pump Pressure (PSIG):
Ignition Control Type:
Pre/Post Purge Feature(s):
Automatic Oil Solenoid Valve:
Combustion Chamber Type:
Clearances to Combustible Materials
(Minimums)
Sides (in.):
Top (in.):
Front (in.):
Rear (in.):
Flue/Vent Pipe (in.):
Supply Plenum Surfaces (in.):

APPENDIX C: SPECIFICATION SHEETS

140,000
114,000
23.5 x 13 (installer must cut opening in lower side casing)
Directly-driven, DWDI, FC centrifugal, w/ 10 in. dia. wheel
R.W. Beckett pressure atomizing type, Model AF
1.00
Preformed, refractory (ceramic fiber matrix material)
VH-BBP
119,000
98,000
70
83
27.8
58
22.25
31
6
53.5 (flue opens upward)
20 x 20
one, 16 x 25
260
120 / 60 / 1
10.2 (w/ R.W. Beckett oil burner)
15
1/2
Permanent split capacitor, 4
1350
5.875, effective
Fixed, flame retention
# 2 distillate (domestic heating oil)
0.85
80
Hollow
130
Interrupted, Direct Spark
None
None
3
3
8
3
9
3
41
105,000
84,000
87,000
70,000
0.75
0.60

Hide quick links: