Download Print this page
Liebert 100 Specification Sheet
Liebert 100 Specification Sheet

Liebert 100 Specification Sheet

Ac power low exposure transient voltage surge suppressor

Advertisement

Quick Links

Liebert AC Power Low Exposure Transient Voltage Surge Suppressor, electronic grade surge
protective device designed with sine wave tracking to protect electronic equipment and
microprocessor-based systems from transients on distribution panels, branch panels, or equipment in
low exposure locations. Dry contacts for remote indication standard.
1: Nominal Voltage Requirements
Nominal Voltage Requirements
L-N
L-L
120 ........N/A....... 120
120 .......208 ...... 120
120 ........240....... 120
N/A ........208....... 208
230 ........400....... 230
N/A ........240....... 240
277 ........480....... 277
N/A ........400....... 400
N/A ........480....... 480
Surge Current Capacity
100 kA/Phase
(L-N: 50 kA + L-G: 50 kA; N-G: 50 kA)
50 kA/Phase
(L-N: 25 kA + L-G: 25 kA; N-G: 25 kA)
25 kA/Phase
(L-N: 25 kA; N-G: 25 kA)
Job Name _______________________
Model #_________________________
Date ___________________________
Qty ____________________________
Quote #_________________________
Liebert Corporation • 1050 Dearborn Drive • PO Box 29186 • Columbus, OH 43229
Phone 607-724-2484 • Fax 607-722-8713 • US & Canada 800-288-6169
EMAIL: info@control-concepts.com • Web Site: www.Liebert.com
AC Power Low Exposure TVSS Technical Specification
Connection Type ................................................. Parallel
Operating Voltage Range................................... +/-15%
Fault Current Rating (AIC).................................. 14 kAIC
Dimensions ..................... .................................... 4.72"x4.72"x2.36"
Operating Frequency Range ............................. 47 – 63 Hz
Capacity................................................................ Continuous
50
EMI/RFI Attenuation ................................... 40 dB
Response Time.................................................... <0.5 ns
Dry Contract rating.............................................. 125vac, 8.0A, 1.0pf
Operating Temperature ...................................... -40ºc to +50ºc
Operating Humidity............................................. 0% to 95%
Status Indication.................................................. LED, Dry Contacts
Certifications........................................................ UL 1449, CUL, CE, ISO 9001
Warranty ............................................................... 5 Years
120 volt systems.................................400 volts all modes
208 through 277 volt systems ..........800 volts all modes
480 volt systems.................................1,500 volts all modes
ORDERING INFORMATION
Building A Model Number: LPL 1 2 3
2: System Configuration
Model ID
L-G
120
120
120
208
230
240
277
400
480
Model ID
100
50
25 – 2
UL 1449 (second edition) Classification
System Configuration
Single (2 Wire + Gnd)
Split (3 Wire + Gnd)
Wye (4 Wire + Gnd)
Delta Hi-Leg (4 Wire + Gnd)
Delta (3 Wire + Gnd)
PANEL I.D.
3: Surge Current Capacity
Model ID
N or L
S
Y
H
D
MODEL NUMBER(S)
82247 Rev 0