  • Page 1: Air Conditioner

    Duct Type Series Slim Duct MSP Duct HSP Duct Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB68-03769A -3...
  • Page 3 features of your new air conditioner • Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest.
  • Page 4: Safety Information

    If you have any questions, call your nearest contact center or find help and information online at www.samsung.com. Important safety symbols and precautions: Hazards or unsafe practices that may result in severe personal injury or death.
  • Page 5 safety information SEVERE WARNING SIGNS WARNING Do not place the air conditioner near hazardous substances or equipment that releases free flames to avoid fire, explosions or injuries. • Potential risk of fire hazard or explosion. Do not install the outdoor unit at an unstable place or elevated surface where there is potential risk of falling.
  • Page 6 Make sure that children take precautions against access to the air conditioner and they do not play with the unit. Do not clean the interior of air conditioner on your own. • You may damage the parts which can cause electric shock or fire •...
  • Page 7 safety information SEVERE WARNING SIGNS (CONT’D) WARNING Use a receptacle that has a ground terminal. The receptacle must be used exclusively for the air conditioner. • Improper electrical grounding may cause electric shock or fire. Be sure to ground the unit. Do not connect the ground wire to gas or water pipes, lighting rods, or telephone grounding lines.
  • Page 8 Do not touch the pipe connected to the air conditioner. Install the indoor unit away from lighting apparatus using the ballast. • If you use the wireless remote control, reception error may occur due to the ballast of the lighting apparatus. Install the outdoor unit where operating noise and vibration will not disturb your neighbor and in a well-ventilated area with no obstacle.
  • Page 9 safety information CAUTION SIGNS (CONT’D) CAUTION Inspect the condition, electric connections, pipes and external case of the air conditioner regularly by a qualified service technician. Do not open doors and windows in the room being cooled during operation unless necessary. Do not block the air conditioner vents.
  • Page 10: Table Of Contents

    contents VIEWING YOUR AIR CONDITIONER Slim duct type MSP duct type HSP duct type USING YOUR AIR CONDITIONER Tips on using your air conditioner CLEANING AND MAINTAINING Cleaning the filter Slim duct type THE AIR CONDITIONER MSP/HSP duct type Maintaining your air conditioner Periodical checks Internal protections via the unit control system...
  • Page 11: Slim Duct Type

    viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. SLIM DUCT TYPE Air filter (the return air side) Ceiling...
  • Page 12: Tips On Using Your Air Conditioner

    using your air conditioner TIPS ON USING YOUR AIR CONDITIONER Here are some tips that you would follow when using your air conditioner. TOPIC RECOMMENDATION • If current outside temperatures are much higher than Cooling the selected indoor temperature, it may take time to bring the inner temperature to the desired coolness.
  • Page 13: Cleaning The Filter

    cleaning and maintaining the air conditioner For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to unplug from the unit for user’s safety. CLEANING THE FILTER When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter captures large particles from the air.
  • Page 14: Msp/Hsp Duct Type

    MSP/HSP duct type 1. Slide out the Air filter on the rear side panel to the right side. 2. Clean the Air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with running water and dry it in a ventilated area. •...
  • Page 15: Maintaining Your Air Conditioner

    cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
  • Page 16: Internal Protections Via The Unit Control System

    Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description The internal fan will be off to against cold air when the heat pump is Against cold air heating.
  • Page 17: Troubleshooting

    appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION • Because of the protective mechanism, the appliance The air conditioner does not operate does not start operating immediately to keep the unit immediately from overloading.
  • Page 18 PROBLEM SOLUTION • Check if the appliance is running in a smoky area or if Odors permeate in the room during there is a smell entering from outside. Operate the air conditioner in Fan mode or open the windows to air out operation.
  • Page 19: Operation Ranges

    appendix OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. OPERATIONAL TEMPERATURE MODE INDOOR HUMIDITY IF OUT OF CONDITIONS INDOOR OUTDOOR Condensation may occur on 64˚F to 90˚F 23˚F to 118˚F the indoor unit with risk to have COOLING or less...
  • Page 20 appendix _19...
  • Page 21 (Spanish) 800-7267 PANAMA www.samsung.com/latin_en (English) 0-800-777-08(Only from landline) www.samsung.com PERU 336-8686 (From HHP & landline) 1-800-682-3180 www.samsung.com PUERTO RICO TRINIDAD & TOBAGO 1-800-SAMSUNG (726-7864) www.samsung.com 0-800-100-5303 www.samsung.com VENEZUELA 1-800-10-SAMSUNG(726-7864) for PLDT 1-800-3-SAMSUNG(726-7864) for Digitel www.samsung.com/ph PHILIPPINES 1-800-8-SAMSUNG(726-7864) for Globe 02-5805777...