Engine-Driven Generators
XCR | contractor/rental
XDR | diesel
XSD | standard-duty
XAF | alternative fuels
XTP | three-phase
Owner's Manual
April 2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the XCR30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Voltmaster XCR30

  • Page 1 Engine-Driven Generators XCR | contractor/rental XDR | diesel XSD | standard-duty XAF | alternative fuels XTP | three-phase Owner’s Manual April 2012...
  • Page 3: Table Of Contents

    Preparing for use ......3.1.9 After long-term storage ....Voltmaster Engine-Driven Generators...
  • Page 4 Battery ........Appendix Power requirements ....... Voltmaster Engine-Driven Generators...
  • Page 5 Minimum extension cord gauge ... Table A-3 Approximate equipment power requirements......Voltmaster Engine-Driven Generators...
  • Page 6 Voltmaster Engine-Driven Generators...
  • Page 7: Introduction

    Model XCR, XSD, and XTP gasoline-fueled generators are EPA certified. Copies of the certificate may be obtained from the factory (see Section 1.5, page 4) or at www.voltmaster.com. Model XDR diesel generators use EPA-certifed Tier 4 engines. Voltmaster Engine-Driven Generators...
  • Page 8: Generator Models

    XCR | contractor/rental XCR30 XCR55 XCR70 XCR80 XCR105 XCR150 XCR180 XDR | diesel XDR50 XDR60 XDR130 XSD | standard-duty XSD30 XSD50 XSD55 XSD70 XSD80 XSD105 XAF | alternative fuels XAF105 XAF150 XTP | three-phase XTP50 XTP80 XTP120 XTP180 Voltmaster Engine-Driven Generators...
  • Page 9: Specifications

    2.2–2.8 0.75–1 XSD50 5000 4000 120/240 33.3/16.7 XSD55 5500 4500 120/240 37.5/18.8 10.8–10.9 7.6–8.3 XSD70 7000 6500 120/240 54.2/27.1 9.5–13.4 7.7–10.3 XSD80 8000 7500 120/240 62.5/31.3 XSD105 10,000 9500 120/240 79.2/39.6 8.5–9 5.8–6 *Depending on engine model. Voltmaster Engine-Driven Generators...
  • Page 10: Xaf Alternative-Fuel Generators

    This information is displayed on the serial number tag, which is adhered to the generator. Contact our service department using the following information: Wanco Inc. 5870 Tennyson Street Arvada, Colorado 80003 800-730-3927 fax 303-427-5725 www.voltmaster.com sales@voltmaster.com Voltmaster Engine-Driven Generators...
  • Page 11: Safety Information

    Keep batteries away from sparks, open flame, and burning objects. ❑ Do not smoke near batteries. ❑ Do not connect or disconnect battery cables from the battery or engine while the unit is cranking or operating. Voltmaster Engine-Driven Generators...
  • Page 12 ■ Do not operate generator in rain, snow, or wet conditions. ■ Installation as a standby generator must comply with all applicable electrical codes, and requires a suitable power-transfer device to isolate generator from power utility. Voltmaster Engine-Driven Generators...
  • Page 13 ALWAYS wear appropriate protective clothing, shoes, and other protective devices, as required by the job. ■ ALWAYS wear appropriate respiratory, hearing, and eye protection. ■ NEVER operate this equipment when not feeling well due to fatigue, illness, or medication. Voltmaster Engine-Driven Generators...
  • Page 14 Only a qualified technician should perform repairs on this equipment, including the installation or replacement of parts and accessories. ■ Use ONLY accessories or attachments that are recommended by the manufacturer. Unauthorized equipment modifications will void all warranties. Voltmaster Engine-Driven Generators...
  • Page 15: Engine Safety

    Spark arresters are qualified and rated by the United States Forest Service. To comply with all applicable laws regarding spark arresters, consult your local Health and Safety Administrator. Voltmaster Engine-Driven Generators...
  • Page 16: Maintenance And Storage Safety

    (+) cable. ■ Keep hands, hair, and tools away from moving parts. ■ Do not wear jewelry or loose fitting clothing while performing maintenance. ■ Use extreme caution if making adjustments while generator is operating. Voltmaster Engine-Driven Generators...
  • Page 17 Only use parts from original manufacturer. ■ Replace operation and safety decals when they become difficult to read. ■ When not in use, store equipment in a clean, dry location out of the reach of children. ■ Before storing, drain fuel. Voltmaster Engine-Driven Generators...
  • Page 18 Voltmaster Engine-Driven Generators...
  • Page 19: Operation

    If the generator is equipped with a fuel shutoff valve, the valve is located under the fuel tank. When using the generator, be sure the valve is open (turned counterclockwise) to permit the flow of fuel from the tank. During transport, the valve must be closed. Voltmaster Engine-Driven Generators...
  • Page 20: Oil

    To select the proper oil: ■ For diesel engines, see the engine manual. ■ For all other engines, see Table 3.1 for oil grade. ■ For gasoline engines, use API Class SG or SH oil (also SG/CD, SG/CE, SH/CD or SH/CE). Voltmaster Engine-Driven Generators...
  • Page 21: Battery For Electric-Start Models

    12VDC, Type U1 300 CCA, max. 5" width except XCR180 Diesel-powered models and 12VDC, 24BCI, 26BCI or 34/78, 400 CCA, XCR180 models max. 6 7/8" width XAF alternative-fuel models 12VDC, Type U1 300 CCA, max. 5" width Voltmaster Engine-Driven Generators...
  • Page 22: Location

    11 inches of water column pressure. Fuel pressure that is too high or too low will adversely affect generator performance. Do not adjust the generator’s fuel regulator, which is preset at the factory. To adjust the fuel mixture, see “Fuel mixture for Model XAF generators” on page 24. Voltmaster Engine-Driven Generators...
  • Page 23 This will prevent debris from entering the generator’s fuel regulator. Check all connections for leaks with soap and water, and stop all leaks before using the generator. Voltmaster Engine-Driven Generators...
  • Page 24: Standby Installations

    Always employ a licensed electrician or electrical contractor to install the power-isolation switch. This is not a do-it-yourself job. Voltmaster Engine-Driven Generators...
  • Page 25: Preparing For Use

    Remove spark plug or plugs Crank the engine slowly Replace the spark plugs and tighten them If the generator worked before being put into long-term storage but no longer works, see the see the Voltmaster troubleshooting manual, available at www.voltmaster.com. Voltmaster Engine-Driven Generators...
  • Page 26: Voltmaster Engine-Driven Generators

    GFCI module. The test is successful if the reset button pops with an audible “click” and the red LED indicator lights up. To reset the generator after a successful test, follow steps 1 through 3, above. Voltmaster Engine-Driven Generators...
  • Page 27: Electrical Loads

    Although diesel models have a minimum load requirement (see “Model XDR diesel generators” on page 22), other generators will not be damaged if operated with no load. Appendix A, page 33, provides information that can help in determining your load requirements. Voltmaster Engine-Driven Generators...
  • Page 28 Receptacles are protected by ground-fault circuit interrupters (GFCI). Consult the National Electrical Code, Underwriters Laboratories or Canadian Standards Association code for ground- fault protection requirements for temporary installations. Voltmaster Engine-Driven Generators...
  • Page 29 With the idler turned on, when an electrical load is applied, the engine speed will automatically return to normal and produce the generator’s rated voltage. For the idler to function, a battery must be connected to the engine. Voltmaster Engine-Driven Generators...
  • Page 30: First-Time Use

    Adjust the fuel mixture screw until the multimeter reads 60 Hz, which ensures optimal generator performance at full speed and maximum load. After adjusting the fuel mixture, tighten the fuel mixture nut to lock the adjustment screw in place. Voltmaster Engine-Driven Generators...
  • Page 31: Starting The Generator

    Model XAF alternative-fuel generators are not affected. ■ Before starting, pump the fuel lever 20 times or more. ■ Do not allow the generator to run out of fuel or to the bottom of the fuel tank. Voltmaster Engine-Driven Generators...
  • Page 32: Starting Procedure

    Before connecting any load to the generator, run the engine for 2 to 3 minutes, allowing it to reach normal operating temperature. Apply loads by inserting plugs into the proper receptacles and turning on connected equipment. See Section 3.2.2 for details about applying loads. Voltmaster Engine-Driven Generators...
  • Page 33: Stopping The Generator

    To stop the engine with this condition you must block the air intake flow until the engine stops. If this situation has occurred, the air filter will be saturated with oil and must be replaced before restarting the engine. Voltmaster Engine-Driven Generators...
  • Page 34: General Maintenance

    The generator should be run at least once a month for a few minutes to keep all components in proper operating condition. For engine maintenance requirements, see the engine manual. For troubleshooting, see the Voltmaster troubleshooting manual, available at www.voltmaster.com. 3.3.1...
  • Page 35: Storage

    Service the air cleaner. Plug the exhaust outlet to prevent moisture, bugs, and dirt from entering. Clean off dirt and grease. Put a cover over the unit and store to avoid extreme heat or cold. Voltmaster Engine-Driven Generators...
  • Page 36: Battery

    Avoid contact with skin, face, and eyes. ■ Wear appropriate eye and hand protection. ■ Upon contact with skin or eyes, immediately flush with water and seek medical help. ■ Keep batteries out of reach of children. Voltmaster Engine-Driven Generators...
  • Page 37 (+) and the green cable is negative (–). ■ Keep battery terminals clean and terminal connections tight. ■ After making connections at the battery terminals, coat the terminals with a light application of petroleum jelly or grease to retard corrosion. Voltmaster Engine-Driven Generators...
  • Page 38 Do not allow cleaning solution or other material to enter battery cells. Rinse batteries with clean water and allow to dry thoroughly. ■ At least once a year, visually inspect terminals and cables for signs of corrosion, especially in hot temperatures. Voltmaster Engine-Driven Generators...
  • Page 39: Power Requirements

    For the approximate starting wattage for appliances with motors, see Table A-1. ■ When using extension cords, refer to Table A-2. ■ For approximate equipment power requirements, see Table A-3. Figure A-1 Formula for calculating wattage × Volts Amps Watts Voltmaster Engine-Driven Generators...
  • Page 40: Electric Motors

    3200 4200 — 2000 2350 3900 5100 — 3000 — 5200 6800 — 4800 — 7500 9800 — *Small appliance NOTE: For pumps, air compressors, air conditioners, and inverters, add at least 25% to start- ing wattage. Voltmaster Engine-Driven Generators...
  • Page 41: Table A-2 Minimum Extension Cord Gauge

    @ 120 volts @ 240 volts length length length 1200 1440 1920 1200 2400 1440 2880 1680 3360 1920 3840 2160 4320 2400 4800 2640 5280 3000 6000 3600 7200 4200 8400 4800 9600 6000 12,000 7200 14,400 — Voltmaster Engine-Driven Generators...
  • Page 42: Requirements

    6-inch element 1500 — 8-inch element 2100 — Sump pump 1/3 HP 1300 1/2 HP 1050 2150 Television — Toaster, 2-slice 1050 — Toaster, 4-slice 1650 — Well pump 1/2 HP 1000 2100 Vacuum cleaner 800–1100 — Voltmaster Engine-Driven Generators...
  • Page 43 5000 gph 2500 10,000 gph 1000 3750 15,000 gph 1500 5000 Welder, electric 70 amp AC 2800 — 200 amp AC 9000 — 230 amp AC @100 amps 7800 — 250 amp AC/DC @75 amps 9800 — Voltmaster Engine-Driven Generators...
  • Page 44 2 HP 1000 2300 Stock tank de-icer 1000 — *The power requirements listed here are estimates. To determine actual wattage for the items you wish to power, refer to owner’s manuals or the data plate on the equipment. Voltmaster Engine-Driven Generators...
  • Page 46 Voltmaster is a Wanco brand. Voltmaster, Wanco, and the Voltmaster and Wanco logos are registered trademarks of Wanco Inc. All other trademarks are property of their respective owners. WANCO INC. 5870 Tennyson Street Arvada, Colorado 80003 800-730-3927 303-427-5700 303-427-5725 fax www.voltmaster.com...