Model XCR, XSD, and XTP gasoline-fueled generators are EPA certified. Copies of the certificate may be obtained from the factory (see Section 1.5, page 4) or at www.voltmaster.com. Model XDR diesel generators use EPA-certifed Tier 4 engines. Voltmaster Engine-Driven Generators...
This information is displayed on the serial number tag, which is adhered to the generator. Contact our service department using the following information: Wanco Inc. 5870 Tennyson Street Arvada, Colorado 80003 800-730-3927 fax 303-427-5725 www.voltmaster.com sales@voltmaster.com Voltmaster Engine-Driven Generators...
Keep batteries away from sparks, open flame, and burning objects. ❑ Do not smoke near batteries. ❑ Do not connect or disconnect battery cables from the battery or engine while the unit is cranking or operating. Voltmaster Engine-Driven Generators...
Page 12
■ Do not operate generator in rain, snow, or wet conditions. ■ Installation as a standby generator must comply with all applicable electrical codes, and requires a suitable power-transfer device to isolate generator from power utility. Voltmaster Engine-Driven Generators...
Page 13
ALWAYS wear appropriate protective clothing, shoes, and other protective devices, as required by the job. ■ ALWAYS wear appropriate respiratory, hearing, and eye protection. ■ NEVER operate this equipment when not feeling well due to fatigue, illness, or medication. Voltmaster Engine-Driven Generators...
Page 14
Only a qualified technician should perform repairs on this equipment, including the installation or replacement of parts and accessories. ■ Use ONLY accessories or attachments that are recommended by the manufacturer. Unauthorized equipment modifications will void all warranties. Voltmaster Engine-Driven Generators...
Spark arresters are qualified and rated by the United States Forest Service. To comply with all applicable laws regarding spark arresters, consult your local Health and Safety Administrator. Voltmaster Engine-Driven Generators...
(+) cable. ■ Keep hands, hair, and tools away from moving parts. ■ Do not wear jewelry or loose fitting clothing while performing maintenance. ■ Use extreme caution if making adjustments while generator is operating. Voltmaster Engine-Driven Generators...
Page 17
Only use parts from original manufacturer. ■ Replace operation and safety decals when they become difficult to read. ■ When not in use, store equipment in a clean, dry location out of the reach of children. ■ Before storing, drain fuel. Voltmaster Engine-Driven Generators...
If the generator is equipped with a fuel shutoff valve, the valve is located under the fuel tank. When using the generator, be sure the valve is open (turned counterclockwise) to permit the flow of fuel from the tank. During transport, the valve must be closed. Voltmaster Engine-Driven Generators...
To select the proper oil: ■ For diesel engines, see the engine manual. ■ For all other engines, see Table 3.1 for oil grade. ■ For gasoline engines, use API Class SG or SH oil (also SG/CD, SG/CE, SH/CD or SH/CE). Voltmaster Engine-Driven Generators...
11 inches of water column pressure. Fuel pressure that is too high or too low will adversely affect generator performance. Do not adjust the generator’s fuel regulator, which is preset at the factory. To adjust the fuel mixture, see “Fuel mixture for Model XAF generators” on page 24. Voltmaster Engine-Driven Generators...
Page 23
This will prevent debris from entering the generator’s fuel regulator. Check all connections for leaks with soap and water, and stop all leaks before using the generator. Voltmaster Engine-Driven Generators...
Always employ a licensed electrician or electrical contractor to install the power-isolation switch. This is not a do-it-yourself job. Voltmaster Engine-Driven Generators...
Remove spark plug or plugs Crank the engine slowly Replace the spark plugs and tighten them If the generator worked before being put into long-term storage but no longer works, see the see the Voltmaster troubleshooting manual, available at www.voltmaster.com. Voltmaster Engine-Driven Generators...
GFCI module. The test is successful if the reset button pops with an audible “click” and the red LED indicator lights up. To reset the generator after a successful test, follow steps 1 through 3, above. Voltmaster Engine-Driven Generators...
Although diesel models have a minimum load requirement (see “Model XDR diesel generators” on page 22), other generators will not be damaged if operated with no load. Appendix A, page 33, provides information that can help in determining your load requirements. Voltmaster Engine-Driven Generators...
Page 28
Receptacles are protected by ground-fault circuit interrupters (GFCI). Consult the National Electrical Code, Underwriters Laboratories or Canadian Standards Association code for ground- fault protection requirements for temporary installations. Voltmaster Engine-Driven Generators...
Page 29
With the idler turned on, when an electrical load is applied, the engine speed will automatically return to normal and produce the generator’s rated voltage. For the idler to function, a battery must be connected to the engine. Voltmaster Engine-Driven Generators...
Adjust the fuel mixture screw until the multimeter reads 60 Hz, which ensures optimal generator performance at full speed and maximum load. After adjusting the fuel mixture, tighten the fuel mixture nut to lock the adjustment screw in place. Voltmaster Engine-Driven Generators...
Model XAF alternative-fuel generators are not affected. ■ Before starting, pump the fuel lever 20 times or more. ■ Do not allow the generator to run out of fuel or to the bottom of the fuel tank. Voltmaster Engine-Driven Generators...
Before connecting any load to the generator, run the engine for 2 to 3 minutes, allowing it to reach normal operating temperature. Apply loads by inserting plugs into the proper receptacles and turning on connected equipment. See Section 3.2.2 for details about applying loads. Voltmaster Engine-Driven Generators...
To stop the engine with this condition you must block the air intake flow until the engine stops. If this situation has occurred, the air filter will be saturated with oil and must be replaced before restarting the engine. Voltmaster Engine-Driven Generators...
The generator should be run at least once a month for a few minutes to keep all components in proper operating condition. For engine maintenance requirements, see the engine manual. For troubleshooting, see the Voltmaster troubleshooting manual, available at www.voltmaster.com. 3.3.1...
Service the air cleaner. Plug the exhaust outlet to prevent moisture, bugs, and dirt from entering. Clean off dirt and grease. Put a cover over the unit and store to avoid extreme heat or cold. Voltmaster Engine-Driven Generators...
Avoid contact with skin, face, and eyes. ■ Wear appropriate eye and hand protection. ■ Upon contact with skin or eyes, immediately flush with water and seek medical help. ■ Keep batteries out of reach of children. Voltmaster Engine-Driven Generators...
Page 37
(+) and the green cable is negative (–). ■ Keep battery terminals clean and terminal connections tight. ■ After making connections at the battery terminals, coat the terminals with a light application of petroleum jelly or grease to retard corrosion. Voltmaster Engine-Driven Generators...
Page 38
Do not allow cleaning solution or other material to enter battery cells. Rinse batteries with clean water and allow to dry thoroughly. ■ At least once a year, visually inspect terminals and cables for signs of corrosion, especially in hot temperatures. Voltmaster Engine-Driven Generators...
For the approximate starting wattage for appliances with motors, see Table A-1. ■ When using extension cords, refer to Table A-2. ■ For approximate equipment power requirements, see Table A-3. Figure A-1 Formula for calculating wattage × Volts Amps Watts Voltmaster Engine-Driven Generators...
3200 4200 — 2000 2350 3900 5100 — 3000 — 5200 6800 — 4800 — 7500 9800 — *Small appliance NOTE: For pumps, air compressors, air conditioners, and inverters, add at least 25% to start- ing wattage. Voltmaster Engine-Driven Generators...
Page 44
2 HP 1000 2300 Stock tank de-icer 1000 — *The power requirements listed here are estimates. To determine actual wattage for the items you wish to power, refer to owner’s manuals or the data plate on the equipment. Voltmaster Engine-Driven Generators...
Page 46
Voltmaster is a Wanco brand. Voltmaster, Wanco, and the Voltmaster and Wanco logos are registered trademarks of Wanco Inc. All other trademarks are property of their respective owners. WANCO INC. 5870 Tennyson Street Arvada, Colorado 80003 800-730-3927 303-427-5700 303-427-5725 fax www.voltmaster.com...