2
PRODUCT IDENTIFICATION
On the back of each module there are 2 labels that provide the following information:
Nameplate: Describes the product type, rated power, rated current, rated voltage, open
circuit voltage, short circuit current, all as measured under STC; weight, dimensions etc.;
the maximum system voltage of 1000V DC.
Warning: The value of Voc times the number of modules in series should
not be bigger than the maximum system voltage marked in the nameplate.
Barcode: This is used to identify each module. Each module has a unique and traceable
serial number in the form of barcode. The barcode of each PHONO SOLAR module has
15 letter/digits.
Warning: Do not remove the nameplate or barcode. The PHONO SOLAR product
warranty will be void if either the module nameplate or barcode is removed.
3
MECHANICAL INSTALLATION
(Note: All instructions hereafter are for reference only.
person or installer must be responsible for the design, installation, mechanical
load calculation and security of the photovoltaic system.)
3.1
Select suitable locations for installation
Select a suitable location for installing the modules.
PHONO SOLAR recommends that to achieve the best performance the modules
should face south in northern latitudes and north in southern latitudes. The exact tilt
angle and orientation of mounted modules should be recommended by a licensed/
qualified installer.
The modules should be completely free of shade at all times.
Do not place the modules near a location where flammable gases are either
generated or collected.
Note
1
: Saline environments can accelerate the processes of electrical insulation losses
and galvanic corrosion, especially when different metals with high electrochemical
potential come into contact each other.
A licensed/qualified
04
In saline environments, Phono Solar PV modules must be installed under the following
conditions:
Modules shall not be installed in locations where they will come into direct contact
with salty water, that is, in offshore (e.g. platforms) and marine (e.g. piers, boats)
applications.
Modules installed in locations where the distance from the sea is less than 500 m
shall fulfill the following requirements:
The modules shall be mounted with a minimum tilt angle of 10° in respect to the horizon;
When fixing the modules using the 8 mounting slots, all the hardware (washers,
screws and nuts) shall be made of stainless steel;
To avoid possible galvanic corrosion between the aluminum frame and the support
structure, PVC washers or neoprene tape shall be interposed between the two metals;
When grounding the module frames, stainless steel hardware must also be used.
Note
2
: In environments where ammonia is present, Phono Solar PV modules must be
installed under the following conditions:
When fixing the modules using the 8 mounting slots, all the hardware (washers,
screws and nuts) shall be made of stainless steel;
To avoid possible galvanic corrosion between the aluminum frame and the support
structure, PVC washers or neoprene tape shall be interposed between the two metals;
When grounding the module frames, stainless steel hardware must also be used.
3.2
Select suitable mounting rails
Please observe the safety regulations and installation instructions included with the
mounting rail. If necessary please contact the supplier directly for further information.
The modules must be safely set onto the mounting rail. The whole rail supporting the
photovoltaic system must be strong enough to resist potential mechanical pressures
caused either by wind or snow, in accordance with local, regional and state safety (and
other associated) standards.
Make sure that the mounting rail will not deform or affect the modules when it
expands as a result of thermal expansion.
The mounting rail must be made of durable, anti-corrosive and UV-resistant materials.
Stability / Reliability / Creativity