Table Of Contents; Introduction - Warmworld FFC 30/60 Installation & Service Instructions Manual

Condensing boilers natural gas only
Table of Contents

Advertisement

Contents
Section
List of Figures
Positions
Fig 8.
Twin Pipe Positions

Introduction

These Instructions cover a range of lightweight, wall
hung, gas fired, condensing boilers which are room
sealed and fan assisted on the flue side. The flue
systems available are Concentric, left, right, or rear,
up to 2 metres and, Twin Pipe, horizontal total
combined length of 22 metres or vertical, up to a
total length of 30 metres. The ignition system is fully
automatic and the boiler incorporates an electronic
modulation gas control.
There are two models with different output ranges -
see the Technical Data on page 1 for details.
The boiler casing is of white enamelled mild steel.
Condensing Boiler
They are suitable for connection to open vented or
sealed systems. These systems may be pumped
central heating or pumped central heating combined
Page
with a pumped indirect domestic hot water circuit.
1
Gravity circuits must NOT be used.
2
3
The boilers include a pump overrun device so it is
3
essential that there is an open circuit for water to
3
flow between the flow and return. In some system
4
designs this may require the addition of a bypass, an
4
automatic bypass is preferred.
4
5
The boilers also contain integral frost protection, the
5
boiler will fire if the temperature within it approaches
5
4 to 5 degrees Centigrade. It will do this even when
6
turned to Off, and can only be inhibited by removing
6
the Permanent Live supply to the boiler.
6
6
Adequate arrangements for completely draining the
6
system, by provision of drain cocks MUST be
7
provided.
7
7
Gas Safety (Installation and Use)
8
Regulations, (as amended).
8
9
It is the law that all gas appliances are installed by a
18
competent person (e.g. a CORGI registered opera-
20
tive) in accordance with the above Regulations.
Failure to install appliances correctly could lead to
Page
prosecution.
11
12
It is in your own interest, and that of safety, to
13
ensure that the law is complied with. The installation
14
of the boiler MUST also be in accordance with the
15
current I.E.E.. Wiring Regulations, the Local Building
16
Regulations, Building Standards (Scotland), the Bye
17
Laws of the Local Water Undertaking, any relevant
requirements of the Local Authority, and Health and
17
Safety document No 635, "Electricity at Work Regu-
23
lations".
24
25
Detailed recommendations are contained in the
25
following British Standard Codes of Practice.
Codes of Practice.
BS.6798 Installation of gas fired hot water boilers of
rated input not exceeding 60kW.
BS.5449:1 Forced circulation hot water systems
(small bore and microbore domestic central heating
systems).
BS.5546 Installation of gas hot water supplies for
domestic purpose (2nd Family Gases).
BS.5440: Part1. Flues (for gas appliances of rated
input not exceeding 60kW).
BS 6891 Specification for installation of low pressure
gas pipework.
BS 7074:1 Application, selection and installation of
expansion vessels and ancillary equipment for
sealed water systems.
2
06/06/01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ffc 65/80

Table of Contents