Troubleshooting Guide - Genie Magic Xtreme Polishing Systems User Manual

Table of Contents

Advertisement

1) INSUFFICIENT WATER TO THE BRUSHES
a) Make sure the solution flow control valve is open.
b) Confirm that there is water in the solution tank.
c) Make sure solution dispensing tubes are not clogged or obstructed.
2) THE MACHINE DOES NOT CLEAN SATISFACTORILY
a) Check the condition of the brushes or pads and replace them if necessary.
b) The brushes should be replaced when the bristles reach a length of 5/8 inches (15mm).
3) THE SQUEEGEE DOES NOT DRY THE FLOOR WELL
a) Check that the squeegee blades are clean.
b) Adjust the inclination of the squeegee.
c) Confirm the vacuum hose is correctly fitted into its port in the recovery tank.
d) Remove the entire vacuum assembly and clean it.
TROUBLE SHOOTING GUIDE