Uses only C
ONTOUR
Wireless Blood Glucose
Monitoring System
®
N
blood glucose test strips from Bayer
EXT

USER GUIDE

® ®
12:00
BG
5.2
mmol/L
Active Insulin 1.5 U
Bolus
Basal

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Contour next Link 2.4 and is the answer not in the manual?

Questions and answers

Summary of Contents for Bayer HealthCare Contour next Link 2.4

  • Page 1: User Guide

    ® ® Wireless Blood Glucose Monitoring System 12:00 mmol/L Active Insulin 1.5 U Bolus Basal Uses only C ® blood glucose test strips from Bayer ONTOUR USER GUIDE...
  • Page 2 INTENDED USE • Always dispose of test strips and lancets as medical waste or as advised by your health care professional. All products that come in contact with human blood should be handled as if The C ® LINK 2.4 wireless blood glucose monitoring system from Bayer (meter, test ONTOUR capable of transmitting infectious diseases.
  • Page 3: Table Of Contents

    Table of Contents о If your blood sugar reading is over 33.3 mmol/L the next screen will tell you to retest. The meter will beep twice. If results are still over 33.3 mmol/L, “Follow Medical Advice Immediately” is displayed. Your C ®...
  • Page 4: Monitoring System From Bayer

    Getting Started The C ® LINK 2.4 Wireless Blood Glucose ONTOUR Monitoring System from Bayer Your C LINK 2.4 wireless blood glucose monitoring system from Bayer only ONTOUR works with C ® test strips from Bayer. ONTOUR Top Menu Button See page 4 Display Screen Meter USB Plug Test Strip...
  • Page 5: Your Contour

    “Talks” to Your MiniMed 640G Insulin Pump Using the Selection/Scrolling Buttons L Button Your C ®  LINK 2.4 meter can ONTOUR OK Button automatically send your blood glucose result 12:00 M Button or a bolus directly to your MiniMed insulin pump, if your meter and pump are linked. This Display mmol/L eliminates the need to manually enter a bolus...
  • Page 6 Set Language LANGUAGE English 3. Press the M button to see more language choices. Utilities 8. In the Utilities menu, use the down arrow to scroll to Deutsch When your language is highlighted, press OK. Self Test Carb Unit Español Device Options.
  • Page 7 When the pump links to the meter, the SN on the meter screen will change to a different serial number. This number is the pump SN. 11. Read pump screen. Be sure other nearby Medtronic devices Auto Connect are NOT in search mode. Use the down arrow to scroll to Before using Auto the next page.
  • Page 8 Meter Send Options High and Low Alerts 17. After the meter and pump are connected, you will need to set your Send Options. This The High and Low Alert feature tells you when your test result is above or below the settings controls how your meter sends blood glucose readings to your MiniMed insulin pump.
  • Page 9: Preparing The Lancing Device

    Testing Target Ranges Next you are asked to accept your blood sugar Targets. Targets are your personal ranges for Getting Ready to Test your blood sugar results. With AutoLog OFF, you have a single Target range. With AutoLog Read your C ®...
  • Page 10: Getting The Blood Drop - Fingertip Testing

    2. Hold the test strip with the grey square end facing up. 2. Loosen the round protective cap on a lancet by rotating it 3. Insert the grey square end into the test strip port until ¼ turn, but do not remove it. the meter beeps (if the Sound is set to ON).
  • Page 11: Test Results

    Apply More Blood Testing With AutoLog On STRIP UNDERFILLED AUTOLOG If the first blood drop is not enough, the meter will beep After you apply blood to the test strip, use the M to select twice and display “STRIP UNDERFILLED” and “APPLY MORE Fasting Fasting, Before Meal, After Meal or No Mark, and then press BLOOD NOW.”...
  • Page 12: Alternative Site Testing (Ast) - Palm

    Alternative Site Testing (AST) – Palm 4. Press the lancing device firmly against puncture site WARNING and then press the release button. • Ask your health care professional if Alternative Site Testing is right for you. • Do not calibrate your continuous glucose monitoring device from an AST result. •...
  • Page 13 AUTOLOG 9. If you have the AutoLog feature turned ON, the WARNING: Potential Biohazard Fasting Fasting, Before AutoLog screen appears. Select • Always dispose of test strip and lancet as medical waste or as advised by your Before Meal Meal, After Meal or No Mark by pressing the OK health care professional.
  • Page 14: Control Solution Testing

    High and Low Blood Sugar Alert Screens Control Solution* Testing Your meter has been preset with a low blood sugar (hypoglycaemia) value of 3.9 mmol/L WARNING and a high blood sugar (hyperglycaemia) value of 13.9 mmol/L. These are the preset values, but can be customized by you and/or your health care professional.
  • Page 15: Autolog (Marking Your Results)

    Features 5. Shake the control solution bottle well, about 15 times before every use. Your C ® LINK 2.4 meter includes many testing features. ONTOUR AutoLog (Marking Your Results) 6. Remove the bottle cap and use a tissue to wipe away any solution around the bottle tip before dispensing a drop.
  • Page 16 Manual Bolus was sent. If Block Mode is ON at the pump, you are asked if you want to proceed with the bolus. Block Mode is a MiniMed pump setting that restricts access to critical pump settings. 7. A confirmation screen appears on both your meter and Please see your MiniMed insulin pump user guide for more detailed instructions.
  • Page 17: Test Reminders

    Test Reminders Changing a Reminder Time 1. Press the L or M button to select the correct hours and minutes (in 15-minute A reminder for your next test can be set after testing OR from the Setup Menu (see page 43). increments).
  • Page 18: Bolus

    Notes Using the Main Menu You may add notes to your test result that may help explain results. Your notes will be saved The Main Menu has 4 choices: Bolus, Logbook, Trends and Setup. To select one, press the L or M button to scroll to your desired selection. When your choice is highlighted, press OK. in the Logbook.
  • Page 19: Trends (Averages And Summaries)

    Trends (Averages and Summaries) 14 DAY RESULTS AVERAGE The Trends feature displays your averages and your results as they compare to your 6. Press the M button to go to the 14 Day Results screen. mmol Results: Results: Targets, over a period of time that you select. The options available are 7, 14, 30 and 90 day averages.
  • Page 20 PUMP OPTIONS 4. The Connect to Pump screens appear next. Press Yes No MiniMed Pump Connect Device 9. Place the meter and pump next to each other. Select Auto Manual Connect connected. Connect now? to connect to a MiniMed insulin pump now. Auto Connect Connect on your pump.
  • Page 21 12. Check that the SN (serial number) on the pump screen matches the meter SN on the meter screen. 12:49 If they match, scroll to Confirm on the pump. Confi rm Device SN BGJ133333F found: SN: Press Select button  16. Hold the back button on the pump until you see the home BGJ133333F mmol/L screen.
  • Page 22 Connecting to the Pump Using Manual Connect NOTE: Place your meter and your pump side by side before you begin. You need to alternate between both devices to complete the connection. 8. In the Device Options menu, scroll to Connect Device. Press Device Options Select button See page 33 for the Auto Connect steps.
  • Page 23 If you have just connected to a pump for the first time, you will be returned to Initial Setup, Meter Send Options, Step 17 (page 10). 11. Place the meter and pump next to each other. Select Search Send Options controls how your meter sends your test results to your pump. You have New Device on your pump.
  • Page 24: Test Reminders

    Changing the Send Option Viewing or Disconnecting Your Pump Connection Your meter must be connected to your MiniMed insulin pump to view pump connection or NOTE: The meter must be connected to your MiniMed insulin pump to set or disconnect from pump. change Send Options.
  • Page 25: Date And Time

    REMINDER 4. To accept the preset time shown, select Start. To Date and Time Start Start COUNTDOWN change the time, select Change and you can change Setting the Date (When Not Connected to a Pump) Change Change the reminder time in 15-minute increments from You can set the date and time on your meter only when the meter is NOT connected to a mins Go Back...
  • Page 26 SETUP Sound Date 3. Press the M button to highlight Time. Press OK Turning the Sound On/Off Time: 11:30 to select. Sound is ON when you receive your meter. Some error messages and the Reminder bell will Sound override the Sound Off setting. 1.
  • Page 27 AUTOLOG Blood Sugar Targets AutoLog is Off. 4. Press Turn On to activate AutoLog. Targets are your personal ranges for your blood sugar results. With AutoLog OFF, you have Accept Accept a single Target range. With AutoLog ON, you have Target ranges for Fasting, Before Meal Turn On Turn On and After Meal.
  • Page 28 Changing Targets With AutoLog On Trends Range NOTE: Targets can only be set inside your selected Alert level(s). For additional The Trends feature displays your averages and your results as they compare to your Targets, over a period of time that you select. The options available are 7, 14, 30 and 90 information, please contact Bayer Diabetes Support.
  • Page 29: Error Detection Displays

    HIGH AND LOW ALERTS Technical Information and Care 4. Choose Accept to use the preset Alert levels (or the mmol/L Alert levels you chose during initial setup) for High and High: 13.9 Accept Accept Transferring Data to CareLink Personal Therapy Low Alerts.
  • Page 30: Battery Status

    Battery Status Rapid Charge Battery Status Displays If the battery is low when you plug in your meter, it will Rapid Charge for about 1 minute. You can run a blood sugar test as soon as Rapid Charge is complete and you have The battery status is displayed with a battery symbol on the Apply Blood screen and unplugged the meter.
  • Page 31: Technical Information

    Symptoms of High or Low Blood Sugar Table 3 — System accuracy results for glucose concentrations between 2.0 mmol/L and 26.5 mmol/L You can better understand your test results by being aware of the symptoms of high or low blood sugar. Some of the most common symptoms are: Within +/- 0.83 mmol/L or +/- 15% 600 of 600 (100%) Low blood sugar...
  • Page 32 Customer Service Information Principles of the Procedure If you have a problem and none of the problem-solving messages on the meter help, contact The C ® LINK 2.4 blood glucose test is based on measurement of electrical ONTOUR Bayer Diabetes Support. Please see back cover for contact information. We have qualified current caused by the reaction of glucose with the reagents on the electrode of the strip.
  • Page 33 Symbols Used System Specifications The following symbols are used throughout the product labeling for the C ® LINK 2.4 ONTOUR Test Sample: Capillary whole blood blood glucose monitoring system (meter packaging and labeling, and reagent and control solution Test Result: Referenced to plasma/serum glucose packaging and labeling).
  • Page 34: Caring For Your Meter

    7. Longo D.L. et al. Harrison’s Principles of Internal Medicine, 18th Edition, 2011. http://www.accessmedicine.com 8. Data on file, Bayer HealthCare Diabetes Care. 9. Tietz Fundamentals of Clinical Chemistry, 5th Edition, Edited by Burtis CA and Ashwood ER, W. B. Saunders Co., Philadelphia, PA, 2001, p. 444.
  • Page 35: Next

    3. Bayer HealthCare reserves the right to make changes in design of this instrument without obligation to incorporate such changes into previously manufactured For warranty service: Purchaser must contact Bayer Diabetes Support for assistance instruments.
  • Page 36 Index Accuracy ............. Customer Service Information ......Menu Button ............Sound On/Off ............Meter ..............Strip Port Light ............. Alerts ..............Date ..............Battery ..............54 Format (Day.Month.Year) or Disposal ..............55 Strips ..............(Month/Day/Year) ..........10 Overview ..............4 High/Low Blood Sugar .........
  • Page 37 Distributed by: Bayer plc Diabetes Care Bayer House Strawberry Hill Newbury, Berks RG14 1JA UK Bayer Limited Diabetes Care The Atrium Blackthorn Road Sandyford, Dublin 18 Ireland Bayer Diabetes Support Group is available from 9:00 am – 5:00 pm, Monday – Friday, on: 0845 600 6030 –...