ELECTRICAL REQUIREMENTS - ELECTRICAL DRYER
When connecting to the terminal block, place the hooked
end of the wire under the screw of the terminal block (hook
facing right), squeeze hooked end together and tighten
screw.
1. Remove center terminal block screw.
2. Remove appliance ground wire (green) from external
ground connector screw. Fasten it under center, silver
colored terminal block screw.
3. Connect ground wire (green or bare) of power supply
cable to external ground conductor screw. Tighten
screw.
1
2
3
1. External ground connector
2. Green or bare copper wire of power supply cord
3. 3/4 in. (1.9 cm) UL-listed strain relief
4. Center silver-colored terminal block screw
5. Neutral grounding wire (green)
6. Neutral wire (white)
4. Place the hooked end of the neutral wire (white wire)
of power supply cable under the center screw of
terminal block (hook facing right). Squeeze hooked
end together. Tighten screw.
5. Place the hooked ends of the other power supply
cable wires under the outer terminal block screws
(hooks facing right). Squeeze hooked ends together.
Tighten screws.
6. Tighten strain relief screws.
7. Insert tab of terminal block cover into slot of dryer rear
panel. Secure cover with hold-down screw.
1 4
3-wire connection: Power supply cord
Use where local codes permit connecting
cabinet-ground conductor to neutral wire.
1
1. 3-wire receptacle (NEMA type 10-30R)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. 3/4 in. (1.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral (white or center wire)
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of
power supply cord to the center, silver colored
4
terminal screw of the terminal block. Tighten
5
screw.
6
1
2
1. External ground connector
2. Neutral grounding wire (green)
3. Center silver-colored terminal block screw
4. Neutral wire (white or center wire)
5. 3/4 in. (1.9 cm) UL-listed strain relief
3. Connect the other wires to outer terminal block
screws. Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of
dryer rear panel. Secure cover with hold-down
screw.
2
4
3
5
7
6