Kortek KTN-2001 Service Manual page 7

Table of Contents

Advertisement

KORTEK Corporation
2) KTN-1401
OPERATING VOLTAGE
OPERATING POWER
LEAKAGE CURRENT TO CHASSIS GNG
AT250VAC,50/60Hz(LINE/NEUT,IN COMMON)
HI-POT LINE/NEUT, IN COMMON
OPERATING TEMPERATURE
REL,HUMIDITY OPERATING
MAGNETIC SHIELD
DEGAUSSING
VIDEO SIGNAL
RASTER DIM ADJUST RANGE HORIZONTAL
RASTER DIM ADJUST RANGE VERTICAL
MODE
PINCUSHION(ALL BRIGHTNESS)
MIS-CONVERGENCE CENTER
MIS-CONVERGENCE CORNERS
VERTICAL
SCAN RATE
HOLD IN RANG
SYNC +5V 74LS LEVELS
LOW
NON-LINEARITY
HORIZONTAL
SCAN FREQUENCY
HOLD IN RANGE
SYNC POLARITY
SYNC +5V 74LS LEVELS
NON-LINEARITY
WHITE BALANCE & LUMINANCE
KTN-2001/1401
PARAMETER
LOW
MIN
TYP
100
115/230
40
50
< 0.40
< 2.0
10
10
INTERNAL
MANUAL TYPE
+0.7Vpp,75 Ohm MONITOR TERMINATIONS
< 250
< 118
15.75 Khz
0.64
1.0
60
5.0
0.0
0.0
15.74
POSITIVE
5.0
5.0
0.0
0.0
X= 281 ±20 y= 311 ±20 Y = 40 ±3 F/L
MAX
UNITS
230
VAC
60
WATTS
0.45
mA
2.4
mA
60
DEGREE
90
%
> 285
mm
> 214
mm
3.0
%
0.7
mm
mm
Hz
±5
Hz
5.0
VOLTAGE
0.6
VOLTAGE
5
%
15.76
Khz
±400
Hz
5.0
VOLTAGE
0.6
VOLTAGE
5
%
Y = 70 ±5 F/L
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ktn-1401