  • Page 2 For the guarantee to be valid, the product must be installed and operated as indicated in this manual. This means it is extremely important that you read the manual. This applies both to the person installing the thermostat and the person who is going to use it. You will also find technical specifications and information on troubleshooting.
  • Page 3: Table Of Contents

    Introduction ..........20 In the pack ..........21 Installing the thermostat ..... 22 How the thermostat works ....26 Troubleshooting ........31 Technical specifications ...... 32...
  • Page 4: Introduction

    Introduction This is a microprocessor-controlled thermostat for optimum regulation of underfloor heating systems. The front is fitted with a lockable knob for regu- lating temperature, as well as an on/off switch that shows whether the under- floor heating is in operation. Temperature control is carried out by means of an algorithm that uses fuzzy technology.
  • Page 5: In The Pack

    In the pack 1. Front for Elko RS, Elko Plus and Gira 2. Adapter for Strömfors frame system 3. Front for Eljo Trend, Merten, Jussi/ Busch-Jäger 4. Frame 5. Thermostat 6. Floor sensor 7. Connection clip Manual...
  • Page 6: Installing The Thermostat

    Installing the thermostat The floor sensor should be mounted in a spiral hose laid in the floor. The hose endings should be sealed so that the floor sensor can easily be replaced. Installation Mount the thermostat in a 65 mm standard appliance box.
  • Page 7 3. Connect power, voltage 230 VAC, load and floor sensor cable. Any extension to the floor sensor cable must be by means of high-voltage current. Protective conductor for incoming feed and for heating cable is connected with a connection clip in the box.
  • Page 8: Getting Started

    Getting started After installation, wait 2-4 weeks before starting the underfloor heating. Precisely how long you wait depends on the type of floor you have and the instructions for the floor putty. Then increase the heat gradually. In order to adapt the underfloor heating system to your own heating requirements as much as possible, it is important that you read the entire...
  • Page 9: How The Thermostat Works

    How the thermostat works This section describes all you need to know about how the thermostat works and how you set it. On/off switch Temp. control Turning off and on The heating is not controlled in stand- by mode. Depress the on/off switch for a second to access stand by mode.
  • Page 10 Control functions The thermostat can regulate the tempera- ture in three different ways. This enables the comfort temperature and any flooring temperature requirements to be combined. How the settings are adjusted is descri- bed on the next page Floor thermostat (F) - A sensor in the floor measures the temperature and then regu- lates the heating accordingly.
  • Page 11 The adjustment of the regulating function, must be done by a qualified electrician. The knob and the front first have to be removed. Disconnect from power supply before removing. Then slide the control to the required position using a small screwdriver. The overheating protection is adjusted here.
  • Page 12 Temperature Regulating function The thermostat regulates the temperature via a sensor in the floor that measures the temperature and regulates the heating accordingly. Set the temperature required Change the floor temperature by turn- ing the knob. Min. position on the con- trol corresponds to 10 °C, max.
  • Page 13 Key lock button When you have found a suitable set- ting for the temperature you can lock the knob. This prevents the control being changed accidentally. See illustration below. First remove the knob. Then move the two plastic parts so that they define the interval required.
  • Page 14: Troubleshooting

    Troubleshooting The underfloor heating Important system is an electrical power installa- tion and any faults must therefore be remedied by a qualified electrician. Fault indication In the event of damage or breakdown of the floor sensor the thermostat switches off and the light starts to flash alternately green and red.
  • Page 15: Technical Specifications

    Technical specifications Voltage 230 VAC-50 Hz Floor temp. range 10-45 °C 16A/230 VAC/Single- Breaking capacity pole Connection cable max 2.5 mm Load cos φ = 1 Hysteresis +- 0.3 °C Protection class IP21 Max. length sensor 50 m, 2x1.5 mm cable Approvals:...