Hide thumbs Also See for ZWP15:

Advertisement

GB
User manual of ZWP15 controller
Contents
1.Description..........................................................................................................................................................2
2.Installation of ZWP15 controller.........................................................................................................................3
3.Controller programming ....................................................................................................................................4
3.1.Adding device to network (INCLUDE function)........................................................................................5
3.3.Associating another controller with the network (LEARN MODE)...........................................................7
3.5.Excluding device from the network (EXCLUDE function)........................................................................9
3.6.Restoring default settings in the controller (DEFAULT function)............................................................10
3.7.Removing SECONDARY controller from the network ...........................................................................10
3.8.Special function ASSAIN A ROUTE........................................................................................................11
4.Technical parameters ........................................................................................................................................11
5.Remote control..................................................................................................................................................12
6.Battery replacement ..........................................................................................................................................13
7.Warranty............................................................................................................................................................14
12.06.01 NC811-GB
1/16
©2012, FAKRO

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZWP15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for fakro ZWP15

  • Page 1: Table Of Contents

    User manual of ZWP15 controller Contents 1.Description................................2 2.Installation of ZWP15 controller.........................3 3.Controller programming ............................4 3.1.Adding device to network (INCLUDE function)..................5 3.2.Associating device with a pair of buttons on the controller (ASSOCIATE function)........6 3.3.Associating another controller with the network (LEARN MODE)............7 3.4.Deleting device from a pair of controller buttons on the controller (DELETE function)......8...
  • Page 2: Description

    The ZWP15 (remote control) enables remote control of electronic accessories compatible with the “Z-Wave” system, e.g. ZWS12 or ZWS30 motors for operating FAKRO roof windows. The ZWP15 controller can operate up to 15 devices separately. The single button in the upper section (No. 3 – Figures 1) allows selecting one of the five channels (No.
  • Page 3: Installation Of Zwp15 Controller

    2. Installation of ZWP15 controller The holder of ZWP15 controller should be attached to the wall or other permanent building element by means of two screws driven into cylindrical plugs inserted into openings drilled in the wall. 1. Screw the bottom section of the holder to the wall using the included screws which are driven into plugs 2.
  • Page 4: Controller Programming

    3. Controller programming In order to operate FAKRO electronic accessories, featuring the Z-Wave system, by means of the ZWP15 controllers, it is necessary to: 1. Add the device to the “Z-Wave” network (INCLUDE function) – see section 3.1 2. Associate the device with a selected pair of buttons on the controller with which user wishes to operate the device (ASSOCIATE function) –...
  • Page 5: Adding Device To Network (Include Function)

    • the device already belonging to other network. It is necessary to use EXCLUDE function and repeat the • procedure of device adding to the network. 12.06.01 NC811-GB 5/16 ©2012, FAKRO...
  • Page 6: Associating Device With A Pair Of Buttons On The Controller (Associate Function)

    • device already belongs to another network or it has not been associated with any network. It is necessary • to perform EXCLUDE function on the device and repeat INCLUDE and ASSOCIATE functions. 12.06.01 NC811-GB 6/16 ©2012, FAKRO...
  • Page 7: Associating Another Controller With The Network (Learn Mode)

    • controller already belonging to another network. It is necessary to perform DEFAULT procedure with it • and repeat associating with the network. 12.06.01 NC811-GB 7/16 ©2012, FAKRO...
  • Page 8: Deleting Device From A Pair Of Controller Buttons On The Controller (Delete Function)

    *) Programming error can be caused by: failure to press programming button within 10 seconds from controller signaling its readiness for • deleting the device from selected pair of buttons; long distance between the controller and device. • 12.06.01 NC811-GB 8/16 ©2012, FAKRO...
  • Page 9: Excluding Device From The Network (Exclude Function)

    When moving the device within the network, it is recommended to delete it from the controller's memory (first deleting from a pair of buttons, section 3.4) an then deleting it from the network (section 3.5) and re-adding after installation in new workplace. 12.06.01 NC811-GB 9/16 ©2012, FAKRO...
  • Page 10: Restoring Default Settings In The Controller (Default Function)

    10 sec. until the moment of signalling the error by the controller or resetting it by removing the batteries. Figure 7: Restoring default settings in controller 3.7. Removing SECONDARY controller from the network Removing this controller from the network consists in restoring default settings with the use of DEFAULT function. 12.06.01 NC811-GB 10/16 ©2012, FAKRO...
  • Page 11: Special Function Assain A Route

    Note !!! All devices taking part in the below procedure must belong to the same network (must have the same HOME ID). It is possible to use the controller (ZWK1, ZWK15, ZWP15) to configure the device being outside the direct range of the network, transferring NODE info of the device which is to be controlled to the controlling device memory (controller), to archieve that use ASSAIN A ROUTE Rysunek 8.
  • Page 12: Remote Control

    (longer than 0.5 sec) and then releasing of the same button. <0,5 <0,5 min 0,5 =0,5 Figure 9: Methods of remote control 12.06.01 NC811-GB 12/16 ©2012, FAKRO...
  • Page 13: Battery Replacement

    Multiple device programming shortens the battery life. 1. Remove the back section of the casing. 2. Replace the battery with a new on. 3. Reinstall the back section of the casing and screw it down in. 12.06.01 NC811-GB 13/16 ©2012, FAKRO...
  • Page 14: Warranty

    14 days after accepting the product for repair. Warranty and post-warranty repairs are performed by the manufacturer i.e. FAKRO PP. Sp. z o.o. Quality Certificate: Device Model............................
  • Page 15 12.06.01 NC811-GB 15/16 ©2012, FAKRO...
  • Page 16 FAKRO PP Sp. z o.o. ul. Węgierska 144A 33-300 Nowy Sącz Polska www.fakro.com tel. +48 18 444 0 444 fax. +48 18 444 0 333 12.06.01 NC811-GB 16/16 ©2012, FAKRO...

Table of Contents