10. WIRING

The appliance shall be installed in accordance with
national wiring regulations.
The heat pump should use separate power supply with
rated voltage.
The external power supply to the heat pump should have
ground wiring, which is linked to the ground wiring of the
indoor and outdoor unit.
The wiring work should be done by qualified persons
according to circuit drawing.
An all-pole disconnection device which has at least 3mm
sepaaration distance in all pole and a residual current
device (RCD) with the rating of above 10mA shall be
incorporated in the fixed wiring according to the national
rule.
Be sure to locate the power wiring and the signal wring
well to avoid cross-disturbance.
Do not turn on the power until you have checked
carefully after wiring.
The power cord type designation is H07RN-F.
Remark per EMC Directive 2004/108/EC
For to prevent flicker impressions during the start of the
compressor
(technical
conditions do apply.
1
The power connection for the heat pump has to be done
at the main power distribution. The distribution has to be
of a low impedance, normally the required impedance
reaches at a 32 A fusing point.
2
No other equipment has to be connected with this power
line.
For detailed installation acceptance please refer to your
3
power supplier, if restrictions do apply for products like
washing machines, heat pumps or electrical ovens.
For power details of the heat pump refer to the rating
4
plate of the product.
For any question contact your local dealer.
5
Connect the cable
10.1
Dissemble the bolts from the cover.(If there isn't a cover on
the outdoor unit, disassemble the bolts from the maintenance
board, and pull it in the direction of the arrow to remove the
protection board.)
Connect the connective cables to the terminals as identified
with their respective mached numbers on the terminal block
of indoor and outdoor units.
Re-install the cover or the protection board.
The Specification of Power
10.2
(Refer to Table10-1~Table 10-8)
10.3
Wiring figure
(Refer to Fig.10-1~Fig.10-6)
installation manual
20
NOTE
process),following
installation
1. Split type outdoor unit
Protection board
2. Vertical discharge type outdoor unit
Protection Board
3. Centrifugal fan outdoor unit
Protection Board
NOTE
All the figures in this manual are for explanation
purpose only. They may be slightly different from the
heat pump you purchased.The actual unit shall prevail.