Analog Inputs:
Only for Satellite 8XS/32
ID:
The ePowerSwitch*8M+
I
followed by "A" or "B" identifies the current input A and B of the ePowerSwitch 8XS /32,
Create new rule:
Click on this button to create a new rule.
Name:
In this field, enter the name you want to give to the two current inputs A and B. The name can be from 1 to
32 characters long and can contain alphanumeric characters.
Do not use quotes or special characters in labels!
Unit:
In this field enter the unit of measurement you want to be displayed.
Graph:
Check this box if you want a display of the analog inputs.
Period (minutes):
In this field enter the period between two measurements.
Power Supplies
ID:
The ePowerSwitch 8M+
PWA
identifies the Power Input A,
PWB
identifies the Power Input B.
Create new rule:
Click on this button to create a new Power Supply rule.
Name:
In these fields, enter the name you want to give to the selected Power supply. The name can be from 1 to
32 characters long, and can contain alphanumeric characters.
Do not use quotes or special characters in labels!
Power Outlets:
ID:
The ePowerSwitch 8M+
O
followed by a number identifies each Power outlet
Create new rule:
Click on this button to create a new rule.
Name:
In these fields, enter the name you want to give to the each Power Outlet of the ePowerSwitch Satellite.
The name can be from 1 to 32 characters long, and can contain alphanumeric characters.
Do not use quotes or special characters in labels!
Default Power-Up:
In the drop-down lists, choose for each power outlet the default status to apply after power-up.
You can choose between:
- "On" if you want the corresponding power outlet to be always switched On after power-up.
- "Off" if you want the corresponding power outlet to be always switched Off after power-up.
- "Last Status" if you want that the corresponding power outlet takes again the state it was in before power
failure.
Power up delay:
In this field, enter the power up delay you want to define for each power outlet. Power up delay means the
delay before the power outlet will take the defined status after power up. The delay can be set between 1
and 255 seconds, the value 0 means that no delay has to be applied after power up.
Function delay:
In this field, enter the delay you want to define before the execution of a function (for example Restart
function of an outlet). The delay can be set between 1 and 3600 seconds.
LOGOUT:
Click "Logout" at the bottom of the page to exit the session without saving changes.
DISCARD CHANGES:
Click "Discard Changes" at the bottom of the page to discard all the changes you have made on this page.
APPLY CHANGES:
Click "Apply Changes" at the bottom of the page to save changes.
R2
automatically creates an ID Code to clearly identify each power input(s).
R2
automatically creates an ID Code to clearly identify each Power supply.
R2
automatically creates an ID Code to clearly identify each Power outlet.