American Water Heater DELUXE SYSTEM Instruction Manual page 27

With single wall heat exchanger for potable water heating only
Table of Contents

Advertisement

system monitoring display
Complete monitoring display
channel indication
toolbar
sYmBol
standard
Relay 1 active
Relay 2 active
Maximum tank limit reached / maximum tank
temperature exceeded.
Antifreeze – function activated
Displayed channel indication is adjustable
system screen
The system monitoring display consists of 3 blocks: channel indication, the tool bar, and
system screen.
The channel indication consists of two lines. The upper line is an alphanumeric 16
segment indication in which the channel name or menu item is shown. The lower 7
segment indication shows the channel value and the adjustment parameters are
indicated.
Temperatures are indicated in °F / °C, Temperature differences are indicated in °F / K
The symbols in the tool bar indicate the current system status
The system screen (active system scheme) shows the scheme selected on the controller.
It consists of several component symbols, which are – depending on the current status
of the system – either flashing, permanently shown or hidden.
flashinG
Collector cooling function active
Collector minimum temperature reached
Collector security shutdown or tank security
shutdown active (max temperature reached).
Sensor error
Manual operation active
Adjustment mode for displayed channel
Blinking control symbols
Pump is blinking while running
Sensors are blinking if the respective sensor
indication channel is selected
Sensors are quickly blinking if there is a sensor error
Operation control lamp indication
Constantly green:
system operation normal
Red/green blinking: initialization phase, manual
operation
Red blinking:
sensor error
27