pump station control instructions

control instructions

Prior to operation of the control on the solar pump station
the collector and tank temperature sensors must be prop-
erly connected. Remove the control cover and connect
the sensors to the proper terminals.
DISPLAY
COVER
CABLE CONDUITS
WITH STRAIN RELIEF
Figure 33.
Figure 34.
The temperature sensors should be connected to the
following terminals with no dependence on polarity:
1 / 2 = sensor 1 (collector outlet)
3 / 4 = sensor 2 (tank bottom)
5 / 6 = sensor 3 (tank top – optional, not included)
7 / 8 = sensor 4 (return flow temperature – optional, not
included)
The power supply is connected to the following terminals:
19 = Neutral - N
20 = Line power - L
12 = Ground
The control is equipped with two relays, one for the
integrated pump in the solar pump station and one for use
in specialty custom applications requiring a second pump:
• Relay 1 (primary pump)
18 = Line power - R1
17 = Neutral - N
13 = Ground
• Relay 2 (secondary pump – optional, not included)
16 = Line power - R2
15 = Neutral - N
14 = Ground

operation and function

OPERATION
CONTROL LAMP
BACKWARDS
PUSHBUTTONS
CAN FUSE 4A
The controller is operated by 3 push buttons below the
display. The forward key (1) is used for scrolling forward
through the indication menu or to increase the adjustment
values. The backwards key (2) is used for scrolling
backward through the indication menu or to decrease the
adjustment values.
For system settings adjustment press the forward key to
reach the last display channel. Then hold the forward
button down for 2 seconds and the system setting screens
can then be shown. If an adjustable value is shown on the
display
Set button (3) so that
button 1 or 2 until the desired value is shown then press
button 3 so that
value is now saved.
26
2
1
3
SET
(SELECTION / ADJUSTMENT MODE)
Figure 35.
is indicated. To change the set value press the
flashes. Adjust the value using
permanently appears. The adjusted