Adjustment Tools; Timing Table; Definition For Normal Condition; B+ Adjustment - NEC N9902 F-1 Service Manual

Hide thumbs Also See for N9902 F-1:
Table of Contents

Advertisement

(1) Adjustment tools:

(A) Color Analyzer
(C) Multi meter
(E) Convergence Meter
(G) Power Meter
(I) DDC test fixture
(2) TIMING TABLE(FACTORY MODE -14 MODES)
MODE
RESOLUTION
1
VGA400
2
VGA640*480
3
640*480(75)
4
640*480(85)
5
800*600(75)
MAC ¢º 50K
6
7
800*600(85)
8
1024*768(75)
9
1280*1024(60)
10
1024*768(85)
11
1280*1024(75)
12
1280*1024(85)
13
1600*1200(75)
14
1024*768(60)
15
Free run Adj.
16
H.CENTERING,EHT

(3) Definition for Normal Condition:

(A) INPUT AC VOLTAGE 110V/50HZ.
(B) WARM UP TIME 30 MINUTES.
(C) CROSSHATCH PATTERN.
(D) ALL VR ADJ CENTER.
(E) CRT FACE TO EAST DIRECTION
(F) COLOR TEMP 9300K

(4) B+ Adjustment:

(A) MODE: 60kHz 1240*768(75)
(B) PATTERN: CROSSHATCH
(C) Adjustment: Adjust VR102 to make the cathode of D112 has 14.9V+0.1V on cathode.
(D) CHECK: CHECK OTHER POWER SOURCE should be 82+2V,7.0+0.3V,
47V+2V,-12.1V+0.5V.
N9902 Adjustment Specifications
(B) CHAROMA 2135 or Function Generator
(D) Hi-Pot Probe
(F) Degauss Probe
(H) Automatic Alignment System
H-SYNC EREQ. V-SYNC FREQ H . POLARITY V . POLARITY
31.4kHz
70Hz
31.4kHz
60Hz
37.5kHz
75Hz
43.2kHz
85Hz
46.8kHz
75Hz
49.7kHz
75Hz
53.6kHz
85Hz
60.0kHz
75Hz
64.0kHz
60Hz
68.6kHz
85Hz
79.9kHz
75Hz
91.1kHz
85Hz
93.7kHz
75Hz
48.3kHz
60Hz
30.0kHz
69Hz
90.1kHz
85Hz