T E R R A S / W - T W I N
f o r
b r i n e - o r g r o u n d w a t e r p l a n t s
T y p e B a s i c
T V
h e a t p u m p
V
IN

Technical information

and assembly
TERRA-SW-TWIN_230V_installation_jul08-engl.cdr
TERRA-SW-TWIN_230V_installation_jul08-engl.cdr
instruction
2 3 0 V
Expenditure July 2008
Expenditure July 2008

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the S-TWIN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Terra S-TWIN

  • Page 1: Technical Information

    - o r g r o u n d w a t e r p l a n t s T y p e B a s i c h e a t p u m p Expenditure July 2008 Expenditure July 2008 TERRA-SW-TWIN_230V_installation_jul08-engl.cdr TERRA-SW-TWIN_230V_installation_jul08-engl.cdr...
  • Page 2: Table Of Contents

    Table of contents Page General Information Heat pump 2.1 Description 2.2 Rang of operation 2.3 Delivery content 2.4 Accessories 2.5 Technical Data- Brine heat pumps Technical Data- Groundwater heat pumps 2.6 Operation limits 2.7 Technical dimensions 2.8 Installation 2.9 Hydraulic schematics 2.10 Connection of the heating side 2.11 Electrical scheme 2.12 Electrical connection...
  • Page 3: General Information

    With the acquisition of this plant you have decided Cleaning: yourself for a modern and economic heating system If required, the Terra heat pump can be cleaned with Regular quality controls and improvements, a damp cloth. The use of cleansers is not recommen- as well as functional tests in the factory, guarantees ded.
  • Page 4: Heat Pump

    As lower the maximal flow temperature is designed as higher is the heat pump effi- ciency TERRA heat pumps operate with the safety coolant R 407 C, which circulates, if properly installed in a clo- sed circuit and is practically no hazard for the envi- ronment.
  • Page 5 5. Technical Data in line with the EN 14511 in line with the EN 14511 - TWIN 2x8 S/W 2x10 S/W 2x12 S/W for brine application Heating output at B 0°C/W 35°C in kW 15,34 18,24 22,56 Heating output at B 0°C/W 45°C in kW 14,86 17,68 21,66...
  • Page 6 - TWIN 2x8 S/W 2x10 S/W 2x12 S/W for groundwater application Heating output at W 10°C/W 35°C in kW 20,16 24,00 30,14 Heating output at W 10°C/W 45°C in kW 20,68 23,04 29,00 Heating output at W 15°C/W 35°C in kW 23,42 27,84 34,76...
  • Page 7: Operation Limits

    (Heating water quality see page 10) Heat pumps have natural pressure resp. tempe- rature operation limits. (See illustration) It is not allowed to operate the TERRA heat pump outside these operational limits. With groundwater heat pumps the groundwater has to have a certain water quality, see page 18. If...
  • Page 8: Technical Dimensions

    2.7 Technical dimensions front side front side right side right side back side back side TERRA 2x8S/W 2x10S/W 2x12S/W 1160 1160 1160 1025 1025 1025 Legend: 1 flow connection R 1 1/2” (use enclosed connection pipe 1 1/4” or 1 1/2”)
  • Page 9: Installation

    2.8 Installation The TERRA heat pump must be installed in a frost protected room by a certified Installation company. The room temperature should be in between 5°C and 35°C. The installation in wet rooms or rooms that are at high risk of dust or explosives is prohibited...
  • Page 10: Hydraulic Schematics

    Buffer Hygienik System scheme 2: System scheme 2: TERRA heat pump with IDM-Hygienik with TERRA heat pump with IDM-Hygienik with dividing membrane dividing membrane The upper part of the buffer is loaded under priority by a priority valve.
  • Page 11 System scheme 3: System scheme 3: TERRA heat pump with IDM-Hygienik and extra TERRA heat pump with IDM-Hygienik and extra heating buffer heating buffer The Hygenik is only used to provide domestic hot The sensor B2 has to be placed inside...
  • Page 12: Connection Of The Heating Side

    2.10 Connection on the heating side The appropriated laws, regulations and Norms for Oxygen diffusion heating installations are also valid for installations If not diffusion proof plastic pipes for the under floor that include heat pumps. heating or a vented heating system is used, it can happen that, if steel pipes, steel radiators or steel buf- fer are installed, corrosion occurs onto these steel It is obligatory to fit a filter into the heating return...
  • Page 13: Electrical Scheme

    The starting current limitation equipment can be in- serted.The starting currents can be reduced around approx. 50% (after pressure balance). For TERRA 5 S till 30 S Art. Nr.: 351 211 Platine IO2, idm.multitalent.wp EEPROM IO2 Fuse 0,5 A t...
  • Page 14: Electrical Connection

    2.12 Electrical connection Before connecting the heat pump, the plastic cover One comment to the problematic of Electro magneti- has to be removed. Now the connectors are accessi- cally compatibility: From year to year more effort and ble. The connectors for the main and grid electricity Know-How is required from manufactures and end are separated.
  • Page 15 Electrical connection for all brine and groundwater heat pumps of the type TERRA Subsequent the necessary connections that are per- formed as inline connections are shown. The gray connections have to be connected on site, whereby the rest is pre connected already.
  • Page 16: Heat Source Systems

    3. Heat source systems 3.1 General Information The given required area for geothermal heat pumps is related to average ground conditions (Soil, clay). The required collector size and therefore the area has to be increased for poor grounds (gravel). Contact your IDM-partner for further consultation. A pump trial run for 48 hours at the end of February and a water analysis is recommended for the use of groundwater.
  • Page 17: Brine Horizontal Collector

    4.2 Range of Application Brine circulation pump and pressure vessel have to be installed onto the flow. Suitable for all heat pumps of type TERRA S The brine pressure vessel has to be connected above the pipes. Attention:...
  • Page 18: Technical Data

    (0,3 0,5mm). Contact your IDM-partner for further consultation. 4.5 Installation schematic An example for a TERRA 8 S-HGL heat pump with 4 circuits and a manifold connection inside the cel- lar. For a length of 2m, where the pipes are brought together, they have to be insulated.
  • Page 19: Brine Bore-Hole System

    The brine pressure vessel has to be connected 5.2 Range of Application above the pipes. Suitable for all heat pumps of type TERRA S. The circuits have to be filled with the anti freeze mixture from the pressure vessel on (because of...
  • Page 20: Accessories

    6. Ground and Surface water systems 6.2 Range of Application 6.1 Description Water inlet temperature : min. +7°C! In this system ground or surface water is used as a he- at source. In the case of groundwater usage the wa- Min.
  • Page 21: Advice For The Installation

    7. Advices for the Installation The heating and brine resp. groundwater circuits ha- ve to be pressure tested, neatly flushed, filled and ca- refully vented before the TERRA heat pump is put in- to operation. Requirements for system start up: The heating system as well as the buffer tank has to be filled and vented.
  • Page 22: Operation

    8. Operation The TERRA heat pump is switched on and off fully au- tomated by the Multi talent control. For a proper operation of the controls the manual has to be looked up. An annual service and maintenance of the installati- on by a customer service is recommended in con- cern of warranty claims.
  • Page 23: Faults / Fault Removal

    9. Faults / Fault removal The heat pump is equipped with a variety of safety ap- plications to protect the machine for possible faults. If the heat pump is contrary to expectation not run- ning, so the following things have to be checked: 9.1 Is the green indicator light inside the main 9.3 Is one of the 5 red fault lights shining? switch shining?
  • Page 24 INBETRIEBNHAME - WARTUNG - SERVICE Unsere Service-Techniker helfen gerne Vorort. Ihren IDM-Servicetechnik regionalen Ansprechpartner mit Kontaktdaten finden www.idm-energie.com Sie auf unserer Website PRAXISWISSEN FÜR VERKAUF UND TECHNIK Das umfangreiche Seminarangebot für Fachleute bei der IDM-Akademie IDM-ENERGIEFAMILIE steht für Sie jederzeit auf unserer www.idm-energie.com Website zur Verfügung.