Users manual TERRA-HGL-Heatpump h e a t p u m p Expenditure Sept 2005 Expenditure Sept 2005 TERRA-HGL_ Bedienung_Sept05-engl.cdr TERRA-HGL_ Bedienung_Sept05-engl.cdr...
22. Time and date setting 23. Display all temperatures Display operating hours and switch impulses 25. Display relais status 26. Display installation details 27. Error display 28. Glossary Changes in technology and Design reserve! IDM-Energiesysteme GmbH, A-9971 Matrei i.O. TERRA-HGL_Bedienung_Sept05-engl.cdr...
With the acquisition of this plant you have decided Cleaning: yourself for a modern and economic heating system If required, the Terra heat pump can be cleaned with Regular quality controls and improvements, a damp cloth. The use of cleansers is not recommen- as well as functional tests in the factory, guarantees ded.
2. General Operation IDM-Mainmenue 30/07/02 11:02 outd- Heat circ A: 20,7°C temp: °C Heat circ B: 21,2°C Heatpump: on Buffertemp.: 52°C 32°C, next Description of Turnkey and funktion keys Turnkey D 1 sets: Change of room temperature inHeat circuit A and/or B out of the main menu “Home”-key (press) out of all other menus Turnkey D 2 sets: Choose a menue point through turning and pressing (= Cursor funktion).
3. The Display in the Main menu Sunshade is displayed in Summer-mode Shows the actual outside temperature Shows the Day and Time Shows the heating circuit operation mode: Heating Circuit Operation with Nominaltemp. IDM-Mainmenue 30/07/02 11:02 clock Heating Circuit Operation with temperature saving 20,7°C outd- Heat circ A:...
4. Set Tap water temperature IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ B: 21,2°C next Heatpump: on 32°C, next Submenu 1- Page 1 General settings next Bufferloading: loading program Settings bufferloading Set power blocking times cooling back next...
Page 7
5. Desired room temperature (Nominaltemperatur) desire - Version 1 IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ B: 21,2°C Heatpump: on 32°C, next for Heat circ A: roomtemperature desired for Heat circ A: 22°C 21°C 20°C for Heat circ B: roomtemperature desired...
Page 8
6. Desired room temperature (Nominaltemperatur) desire - Version 2 IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ A / B: Heat circ B: 21,2°C Heatpump: on 32°C, next Heat.circ. A function: heating program next constant at: 35°C settings heating program non freezing: back...
7. Room influence setting IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ A / B: 21,2°C Heat circ B: Heatpump: on 32°C, next Heat.circ. A function: heating program next constant at: 35°C settings heating program non freezing: back next...
8. Characteristic Curve Settings IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ. A / B: 21,2°C Heat circ B: Heatpump: on 32°C, next Heat.circ. A function: heating program next constant at: 35°C settings heating program non freezing: back next...
9. Set the operation mode of the Heating Circuits IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C 21,2°C Heat circ B: Heat circ A / B: Heatpump: on 32°C, next function function Heat.circ. A function: heating program constant at: 35°C always high level settings heating program...
10. Heat program setting IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C 21,2°C Heat circ B: Heat circ A / B: Heatpump: on 32°C, next Heat.circ. A function: heating program settings heat program constant at: 35°C settings heating program non freezing: back next...
11. Mode of bufferloading IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C 21,2°C Heat circ B: next Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program Settings bufferloading Set power blocking times bufferloading cooling back next...
12. Heat program setting IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: Weiter °C 21,2°C Heat circ B: Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program Settings bufferloading Settings bufferloading Set power blocking times cooling back next...
13. Setting power blocking times IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: next °C Heat circ B: 21,2°C Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program Set power blocking times Settings bufferloading Set power blocking times cooling back...
14. Heatpump connection IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: next °C Heat circ B: 21,2°C Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program General Settings Settings bufferloading Set power blocking times cooling back next...
15. Automatic heatpump connection IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C next 21,2°C Heat circ B: Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program General Settings Settings bufferloading Set power blocking times cooling back next...
16. Loading buffer once IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C 21,2°C Heat circ B: Heatpump: on 32°C, next bufferloading Actual buffer temperature: 47°C Loding buffer once Desired tap water temp.: 48°C Loading buffer once: back back In the “bufferloading”...
18. Activate precence operation IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C 21,2°C Heat circ B: Heatpump: on 32°C, next Precence operat. Precence operat.: off Presence operat.: Changing of the setted heating program Till the next switch over for the heating circuit in work back back...
20. Cooling IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Next 21,2°C Heat circ B: Heatpump: on 32°C, next Submenu 1- Page 1 General settings Bufferloading: loading program Cooling Settings bufferloading Set power blocking times cooling back next Cooling heat circ.
21. Cement floor heat program Change as described under point 4 in the Submenu 1 - Page 2 “Submenü 1 - Page 2” Settings domesticwater Cement floor-heating program Cement floor heat. prog. back for heat circ: Cement floor heating program for heat circ.: Heat circ.A and B heat circ A and B start temperature: 25°C...
22. Date and time setting IDM-Mainmenu 30/07/00 11:02 clock outd- Heat circ A: 20,7°C temp: °C Heat circ B: 21,2°C next Heatpump: on 32°C, next General settings Submenu 1- Page 1 General settings Bufferloading: loading program Settings bufferloading Set power blocking times cooling back next...
27. Error Display A Varity of errors can be recognised and displayed by the IDM-Hauptmenü 30/07/00 11:02 Uhr control unit.. Außen- Heizkreis A: 20,7°C The red LED shines in case of an error. The illustration temp: °C 21,2°C Heizkreis B: shows the position of the displayed error.
28. Glossary Nominaltemperature: Desired temperature during the adjusted heat times (usually during the daily), standard attitude = 20°C.. Nominaloperation: The respective heating circuit is operated in such a way that in the appropriate areas the nominal temperature (computational) adjusts itself. Nominaloperation time: That time, in which the nominal temperature for the heating is valid (standard: 6:00 till 22:00h )