Troubleshooting

1. If the cooler does not run:
Check the supply voltage is available at the socket and check that the power plug is
correctly connected.
2. If the cooler does not become cold enough:
a. is the thermostat is set properly?
b. is there enough space around the cooler?
c. is the door is opened too frequently or not closed properly? (check seals).
d. is there direct sun shine on the appliance or are there heat sources nearby?
e. is there too much foodstuff inside the compartment? (Do not put hot liquids in the
cooler)
f. is there dust and debris built up on cooling matrix or compressor?
3. If the cooler operates noisily:
a. Check that the appliance is installed on a stable, level floor. Adjust the feet if nec-
essary. Is the cooler is too near the wall?
b. The food stored in the cooler is not touching - particularly applies to glass contain-
ers. The cooler creates very slight vibrations, which can be amplified greatly with
touching glass containers!
Note:
During high relative humidity environment, condensation may occur on the surface
of the cooler. This is not a malfunction. Simply clean the surface of condensation.
If the cooler is not working properly after all these checks, contact the service
center without further delay.