PROBLEM
Engine will not start or starts
and runs rough
Engine suddenly stops
No power at AC receptacle
Speed of starter motor drops
after period of time.
TABLE 7. Troubleshooting — Probable Causes and Solutions
HW7500E/HW7500EL Portable Electrical Generator Owner's Manual
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poi-
son you cannot see or smell.
NEVER use inside a home
or garage, EVEN IF doors
and windows are open.
PROBABLE CAUSE
No fuel.
Stale fuel.
No or low engine oil.
Spark plug wire (cap) disconnected.
Faulty/bad spark plug.
Fuel not reaching carburetor.
Dirty air filter.
Dirty spark arrestor screen.
No fuel.
No or low engine oil.
Electrical overload on generator.
Poor connection or defective cord set.
Connected electrical appliance/
equipment is defective.
Battery is losing charge.
WARNING
Only use OUTSIDE and far
away from windows, doors, and
vents.
Add fuel (page 24).
Drain fuel tank; fill with fresh fuel (page 30).
Add engine oil (page 22).
Install spark plug cap over spark plug.
Check/replace spark plug (page 28).
Clean fuel sediment cup (page 27).
Clean or replace air filter (page 25).
Clean spark arrestor screen (page 29).
Add fuel (page 24).
Add engine oil (page 22).
Check all circuit breakers for
"tripped' position or overload
indicator light on. Reduce elec-
trical load on circuit, wait several
minutes, and then push to reset
circuit breaker.
Check cord connection. Replace defective cord
set.
Check electrical appliance/equipment for defects.
Disconnect defective appliance/equipment from
the generator. Have appliance serviced by quali-
fied repair facility.
Recharge battery.
SOLUTION
Set
www.honeywellgenerators.com
Tripped
31