AUTOMATIC & MANUAL
MODELS:
INSTALLATION & OPERATING
INSTRUCTIONS
IMPORTANT
PLEASE READ THIS LEAFLET CAREFULLY
AND RETAIN FOR FURTHER USE
NOTE ALSO THE INFORMATION
GIVEN ON THE HEATER
The Installation must be carried out by trained
personnel.
A means for disconnection must be
incorporated in the fi xed wiring by a double pole
switch with a contact separation of a minimum
of 3mm and in accordance with the current IEE
Wiring Regulations.
The heater must not be installed immediately
below a fi xed socket outlet.
The heater is not suitable for connection to a
30A ring circuit.
Do not position the heater under windows
where curtains can contact the heater casing.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal operation.
Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST
BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure
that they do not play with the appliance.
This appliance is very heavy and must be securely fi xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES
ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface.
This heater must be installed where it is impossible for switches and other controls to be touched by a person
using a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the fi rst few days of
operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS
WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING
THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS
DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL
PART.
STORAGE HEATER RANGE
SH6 - 6kWh
SH18 & SH18A - 18kWh SH24 & SH24A - 24kWh
SH12 & SH12A - 12kWh

Advertisement

loading

Summary of Contents for Vent-Axia SH6

  • Page 1 AUTOMATIC & MANUAL STORAGE HEATER RANGE MODELS: SH6 - 6kWh SH12 & SH12A - 12kWh SH18 & SH18A - 18kWh SH24 & SH24A - 24kWh INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE...
  • Page 2 Four fi xing positions must be chosen for the SH24, three for SUGGESTED FIXINGS the SH18 and two for the SH12 and SH6. Mark the positions for the fi xing holes - two at the extreme ends and the others SOLID BRICK/BLOCK: No.
  • Page 3 On the SH24 remove the element to the right of centre, on the SH18 remove the central element, on the SH12 the left hand element should be removed and, on the SH6, there is only one element. Loosen the two screws securing the element tails in the ceramic connector block, and lift the element up and out of the heater.
  • Page 4: Control Functions

    (such as soot or incense SETTING THE CONTROLS generated from the burning of candles etc.). The controls are located on the top panel. There are no user adjustable controls on the SH6. RECYCLING CONTROL FUNCTIONS For electrical products sold within the European Community.

This manual is also suitable for:

Sh18Sh18aSh12Sh12aSh24Sh24a