The Savant SmartVideo (SSV-1000) Quick Reference Guide provides all the steps necessary
to get the Savant SmartVideo Controller up and running.
Specifications
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 80% RH (non-condensing)
Maximum BTUs
115 BTUs per hour
Cooling
6 cubic feet per minute (CFM) recommended
Height
1.75 in/4.4 cm
Width
17.3 in/44 cm
Depth
8.5 in/21.5 cm
Weight
10 lbs/4.5 kg
Input Power
100 - 240 VAC, 50/60 Hz, Max Current 1.8A, Fuse 250V, 2.5A Fast
Acting
Nominal Input Power: 22W (50VA) for 120V AC, 60Hz (N. America)
Maximum Input Power: 33W (75VA) for 120V AC, 60Hz (N. America)
Nominal Input Power: 22W (50VA) for 230V AC, 50Hz (Europe)
Maximum Input Power: 33W (75VA) for 230V AC, 50Hz (Europe)
Safety and
CSA NRTL/C and FCC Part 15 Class B
Emissions
RoHS
Compliant
Install Kit
The standard install kit contains the following items:
Qty.2 071-0603-00 Rack Mounting Brackets
Qty.4 039-0017-00 Screws for Brackets
Qty.1 064-0079-00 AC Power Cord
Qty.2 028-9352-00 6 Position Connectors for IR ports
Qty.2 028-9351-00 3 Position Connectors for GPIO and Relay ports
Front
1
On/Off button
Used to power the Controller On and Off. The I/O power
switch on the back of Controller must be On (I) to enable
the Controller.
2
Reset button
Press to reset the SSV-1000
3
Power Bi-color LED
Green indicates the system has adequate power and is
operating normally.
Red indicates the system is in stand-by mode. In standby
most of the Controller circuitry is powered down.
Off indicates that the system is getting no power.
4
Status Bi-color LED
Green indicates the Host has established communications
with the embedded system.
Green flashing indicates the embedded system is ready
(running with DHCP IP address), but the Host has not
established communications with the embedded system.
Off indicates the embedded processor is resetting or is
powered up; and is booting the embedded firmware.
Red indicates the Host has determined the firmware needs
to be updated, but a problem occurred during the process
that will initiate a reset.
Red flashing indicates the embedded firmware is running,
but has not received a DHCP IP Address.
Amber indicates the Host is currently updating the
embedded firmware.
Amber flashing indicates the embedded system has a
valid link-local IP Address and is waiting to connect to the
Host.
Over Temperature or Hardware Failure
If the Controller over heats or has a hardware failure, the
Status LED indication will be interrupted every 3-seconds
with a solid red indication. For example, if the LED is
flashing green when an over temperature or hardware
failure occurs, the LED, in 3-second intervals, will flash
green, solid red, etc.
5
RS-232 LED
Green indicates RS-232 serial port data activity.
Off indicates no RS-232 serial port activity.
6
GPIO LED
Green indicates GPIO port signal activity.
Off indicates no GPIO port activity.
7
OSD Present LED
Green indicates the external host is connected to the Host
HDMI port.
Off indicates the external host is not connected to the Host
HDMI port.
8
Video LED
Off indicates the encrypted video content remains
protected. The HDCP keys remain valid.
Red flashing indicates the HDCP keys are invalid.
9
IR LED
Green indicates IR port signal activity.
Off indicates no IR port activity.
10
Relay LED
Green indicates Relay port signal activity.
Off indicates no Relay port activity.
SmartVideo (SSV-1000) Quick Reference Guide
Copyright
2011 Savant Systems LLC. SAVANT
Savant LLC reserves the right to change product specifications without notice.
770 Main Street, Osterville, MA 02655, Phone 508.683.2500, Fax 508.683.2600, http://www.savantav.com
Rear
Power
1
On/Off (I/O) power switch
Control
2
Ethernet
3
RS-232 1, 2
4
GPIO R, COM, 1
5
Relay NC, C, NO
(Normally Closed, Common,
Normally Open)
6
IR 1, 2, 3, 4, 5, 6
7
Host HDMI
8
Digital Audio Out
9
HDMI Out
10
Video Component In Y, Pr,
Pb
11
Audio In
12
HDMI In 1, 2, 3, 4
RS-232 Wiring
Controller RJ-45 (RS-232) Plug Pinouts
1 RX+
(Not Used for RS-232)
2 RX-
(Not Used for RS-232)
3 TX+
(Not Used for RS-232)
4 GND (RS-232)
Important
If you are using RJ-45 to DB-9 adapters not supplied by Savant be sure to terminate any wires
required for communication/control within the adapter. Cut all unused wires to prevent the
wires from shorting against each other. Ensure that all wires required for
communication/control are not terminated in the connecter. Also, ensure that these unused
wires are not shorting to each other, as they are still terminated in the RJ-45 connector on the
controller side.
RS-232 Cat5 Savant Controller to DB9 Connections (Straight)
* Use only if Flow Control is required
RS-232 Cat5 Savant Controller to DB9 Connections (Null Modem)
* Use only if Flow Control is required
IR Port Layout and Pinouts (2 - 6-pin 3.8mm screw down
connectors)
and RacePoint Blueprint are trademarks of Savant Systems LLC.
009-0313-00
Press the I/O switch to (I) to power on the Controller.
Press the switch to (O) to power off the Controller.
RJ-45 10/100 Base-T, auto-negotiating port
RJ-45 ports used to transmit and receive serial binary
data transmission. Ports 1 and 2 support flow control
Clear to Send / Ready to Send (CTS/RTS)
General Purpose Input and Output port (3-pin
3.81mm screw down connector)
This port provides dry contacts (open/closed) to
control devices requiring basic on/off operation. (3-pin
3.81mm screw down connector)
Infrared transmitter output ports (Two 6-pin 3.81mm
screw down connectors)
Input port for external host (Mac mini)
Output port supports TOSLINK
HDMI output port to HDTV (for example)
RCA jacks - Component
R and L RCA jacks
Input ports for sources (DVD, Apple TV, etc.)
5 RXD (RS-232)
6 TX-/TXD
(TDX for RS-232)
7 CTS (RS-232)
); ports 1 and 2
8 RTS (RS-232)
); ports 1 and 2

Advertisement

loading
Need help?

Need help?

Do you have a question about the SmartVideo SSV-1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Savant SmartVideo SSV-1000

  • Page 1 Important Qty.1 064-0079-00 AC Power Cord If you are using RJ-45 to DB-9 adapters not supplied by Savant be sure to terminate any wires Qty.2 028-9352-00 6 Position Connectors for IR ports required for communication/control within the adapter. Cut all unused wires to prevent the Qty.2 028-9351-00 3 Position Connectors for GPIO and Relay ports...
  • Page 2 IP traffic between Savant Network Equipment. When configuring the network ensure that all of the connected Savant units (SSV-1000 and HST-3001) are on the same local area network (subnet or LAN). Being on the same subnet allows the Savant units to locate each other using the Bonjour network protocol.