Note: One drive IC fails on the YDT or YDB board
fails causing the successive drive ICs to not function.
This symptom (a Black Bar less-than ½ the screen )
can be located in the top or bottom half of the screen
depending on if the failed IC is on the YDT or YDB
XR address Board
board .
Single Horizontal Black Line (upper half of screen )
st
– Confirm secure
nd
2
– Check the drive ICs on
the YDT board for physical
damge .
Replace YDT board if Ics are
damaged .
Single Horizontal Black Line (lower half of screen )
st
nd
2
– Confirm secure
– Check the drive ICs on
the YDB board for physical
damage .
Replace YDB board if ICs are
damaged .
Single Defective Driver Board Buffer IC on YDT or YDB Board
st
– Replace the YDT or YDB
FWD50PX2 Troubleshooting