1712
This circuit is the modification carried out to fit NVR system to UK requirements, therefore use this diagram
for the control circuit.
L
N
white
Note:- K1 is fitted inside a box underneath the machine
Reproduction of this information is prohibited without the written consent of HOBART STILL.

WIRING DIAGRAM

white
K1
Indicator
lamp
MOTOR
UK. SERVICE TRAINING CENTRE
Warning this information is for HOBART STILL trained personnel only.
Stop
K1
Start
blade
guard
switch
K1
The blade guard switch is not fitted on
later machines that have a blade guard
protection ring and is therefore linked
out