Diagnostic Error Code
018-250-XXX PCI Card Services error
020-000-XXX PCI Interface Test Passed
020-0XX-XXX PCI Interface error
020-195-XXX PCI Test aborted by user
020-196-XXX PCI test halt, error threshold exceeded
020-197-XXX PCI test warning
020-198-XXX PCI test aborted
020-199-XXX PCI test failed, cause unknown
020-262-XXXPCI system error
025-000-XXXIDE interface Test Passed
025-00X-XXX 025-01X-XXX IDE interface failure
025-027-XXX IDE interface Configuration/Setup error
FRU/Action
1. PCI card
2. Riser card, if installed.
3. System board
No action
1. PCI card
2. Riser card, if installed.
3. System board
Information only Restart the test, if necessary
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
1. Make sure the component that is called out is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
1. If a component is called out, make sure it is
connected and/or enabled. See Chapter 6 "Using
the Setup Utility program" on page 57.
2. Flash the system and re-test. See "Flash update
procedures" on page 167.
3. Go to "Undetermined problems" on page 82.
1. Go to "Undetermined problems" on page 82.
2. Flash the system and re-test. See "Flash update
procedures" on page 167.
3. Replace component under function test.
1. PCI card
2. Riser card, if installed.
3. System board
No action
1. IDE signal cable
2. Check power supply voltages.
3. Reseat IDE signal cable.
4. IDE device
5. System board
1. IDE signal cable
2. Flash the system. See "Flash update procedures"
on page 167.
3. Reseat IDE signal cable.
4. IDE device
5. System board