Summary of Contents for Thrane&Thrane TT-3042D

  • Page 1 Remote Alarm TT-3042D Manual...
  • Page 3 Thrane & Thrane Thrane & Thrane Remote Alarm TT-3042D Manual Copyright © Thrane & Thrane A/S ALL RIGHTS RESERVED...
  • Page 4 Information in this document is subject to change without notice and does not represent a commitment on the part of Thrane & Thrane A/S. © 1998 Thrane & Thrane A/S. All right reserved. Printed in Denmark. Document Number TT98-110040-A. Release Date: 23 June 1998...
  • Page 5 Safety Summary Safety Summary The following general safety precautions must be observed during all phases of operation, service and repair of this equipment. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture and intended use of the equipment. Thrane &...
  • Page 6 This page is intentionally left blank...
  • Page 7: Table Of Contents

    Table of Contents Table of Contents Table of Contents 1 Description ..................1 1.1 Specifications ................ 2 1.2 Detailed description ............. 3 1.3 Configuration ................ 5 1.4 Installation................8 1.5 Connectors................10 1.5.1 X1 Power In ..............10 1.5.2 X2 I/O ................10 2 Operation..................
  • Page 8 Table of Contents Table of Contents This page is intentionally left blank Page ii ii Page 7Jul98 7Jul98...
  • Page 9 Table of Contents Table of Contents 7Jul98 7Jul98 Page Page iii iii...
  • Page 11: Description

    Description 1 1 Description Description This manual provides information for configuring, installing and operating the TT-3042D Remote Alarm. For general information regarding the Arcnet standard please refer to ATA Standards Committee’s ‘ANSI/ATA 878.1 Local Area Network: Token Bus (2.5 MBPS)’.
  • Page 12: Specifications

    Description Description Specifications Specifications Specifications Specifications Indication Visual: LED indicators with dim function. Text back-light with dim function. Call reset OK button Distress transm. Patch covered button with 5 sec activation delay. Arcnet/serial port DB 15M conn: Arcnet: Twisted pair/bus topology, max 100 meter cable.
  • Page 13: Detailed Description

    The TT-3042D includes a distress button, allowing direct transmission of distress calls from the unit. A navigator with NMEA 0183 output can be connected directly to the TT-3042D for routing of position data back to the Capsat transceiver for automatic update of e.g. safety and distress information.
  • Page 14 Indicator and text background light level is selected by front panel operation. The TT-3042D is equipped with remote turn-on for power saving configurations. Remote turn-on is enabled by jumper setting. Page 4 4 Page...
  • Page 15: Configuration

    If this is ignored, the Arcnet will not operate properly. The TT-3042D Remote Alarm is configured by setting an 8 position DIP switch located under the paper inlet. To set operating parameters remove paper and turn off power.
  • Page 16 Description Description Configuration Configuration Position Setting Fact. Address off,off,off: off,off,on: off,on,off: off,on,on: on,off,off: on,off,on: on,on,off: on,on,on: Printing Direction Reverse off: Normal Sounder Timeout 10 sec. Timeout off: no timeout NMEA/Aux.Port NMEA 0183¹ NMEA off: Serial data² Dot Energy High High off: Normal Printing Width...
  • Page 17 Configuration Configuration Description Description Table 1: DIP switch settings. Jumper Function Fact. Watchdog Only for debugging Short connect NMEA 0183 in 1-2: Opto isolated Optoisolated 2-3: Rx/Tx return to GND Remote Turn- 1-2: Enable 2-3: Permanent On Arcnet Balanced Open balanced NMEA 0183 out 1-2: Balanced...
  • Page 18: Installation

    Installation Installation Installation Installation To following brief outline may be used to get the TT-3042D up and running as a printer together with a Thrane & Thrane transceiver which supports Arcnet - hardware as well as software wise. 1. Set an unique Arcnet address as described in section 1.5.2.
  • Page 19 Installation Installation Description Description • Always use shielded twisted pair cables and shielded connectors (otherwise the EMC specifications are not guarantied to be fulfilled). • The length of the cable making up the Arcnet bus should be no longer than 100 meters. •...
  • Page 20: Connectors

    Description Description Connectors Connectors Connectors Connectors 1.5.1 X1 Power In The pinout of the power supply input is as listed below. Function Sec. Battery Positive Battery Negative Ground Remote turn-on 2.1.13 1.5.2 X2 I/O The pinout of the I/O connector (15 pole SubD) is listed below. Function Distress/Urgent, 100 Ohm, Open Collector Safety, 100 Ohm, Open Collector...
  • Page 21: Operation

    Connectors Operation Operation 2 2 Operation Operation The TT-3042D Remote Alarm for the Capsat series of Inmarsat-C transceivers operates as a message and status printer, it also displays the general system status. 2.1.1 Distress Transmission Distress transmission is activated by lifting the protective cover and pressing the Distress button for 5 seconds.
  • Page 22: Status Indicators

    Operation Operation Connectors Connectors 2.1.2 Status Indicators Power: The power diode is used as a power-on indicator, furthermore this diode indicates communication status with the transceiver. When the transceiver is turned off or the Arcnet connection is disconnected, the power diode is flashing to indicate the fault situation.
  • Page 23: Mail Indicator

    The sounder timeout option, set by the DIP switch, must not be enabled when the TT-3042D is used as a remote alarm. The sounder timeout option must only be enabled when the remote alarm is used for printing only. When the timeout option is set the sounder will not be turned on for more than 10 seconds.
  • Page 24: Paper Feed

    6. Insert the paper roll in holder and close the roll holder. 2.1.10 Paper Saving For paper saving the TT-3042D cuts away succeeding blank lines. A maximum of two blank lines are allowed after each other. In 40 chars per line mode succeeding spaces are also cut away.
  • Page 25: Dot Energy

    15V) signal levels are accepted. The NMEA 0183 input is optical isolated when jumper W2 is in position 1-2 (low). The TT-3042D automatic detects if a NMEA 0183 navigator output has been connected. Standard NMEA 0183 messages are read, position and velocity data extracted and transferred to the transceiver.
  • Page 26: Nmea 0183 Sentence Output

    The NMEA 0183 communication parameters are: 4800 baud, 1 stopbit and no parity. Hint: To test the NMEA 0183 link the TT-3042D can be configured to serial data input on NMEA 0183 port, see section 1.5.2, NMEA 0183 sentences should then be printed out.
  • Page 27: Remote Turn-On

    4800 baud, the same as for NMEA data input. The port parameters are fixed. 2.1.16 Remote Turn-On In power saving applications the TT-3042D can be turned on remotely. Jumper W3 must then be set in position 1-2 or the Remote Alarm will be turned on permanent.
  • Page 28 Operation Operation Connectors Connectors This page is intentionally left blank Page 8 8 Page 7Jul98 7Jul98...
  • Page 29: Fault Diagnostics

    Fault Diagnostics Fault Diagnostics Fault Diagnostics Fault Diagnostics 3 3 Fault Diagnostics Fault Diagnostics If power diode does not turn on check fuse, voltage source and remote turn-on setting. If power diode is blinking then Arcnet connection to transceiver is failing. First check if transceiver is turned on, then check the Arcnet cabling, if no result then check Arcnet address settings for all units coupled to transceiver.
  • Page 30 Fault Diagnostics Fault Diagnostics Fault Diagnostics Fault Diagnostics This page is intentionally left blank Page 2 2 Page 7Jul98 7Jul98...
  • Page 31: Outline

    Outline Outline Outline Outline 4 4 Outline Outline 7Jul98 7Jul98 Page Page 1 1...